Background: Bakery workers due to exposure to radiant heat and doing manual labor are at risk of heat-related illnesses and musculoskeletal disorders Objectives: The current study aimed to determine the appropriate work-rest time interval using two indexes of wet bulb globe temperature (WBGT) and relative heart rate (RHR). Methods: It was an analytical and descriptive research. Heart rate of workers was continuously recorded to achieve the physiological monitoring and the obtained information was used to determine the work difficulty and physical workload. The ratio of heat stress and RHR was measured using the WBGT and polar team pro device, respectively. Work-rest schedules were detected through
Background
Precise causes of musculoskeletal complaints among nurses are not known well, but many studies have pointed to manual patient handling tasks. Subjective judgment and decision-making process for patient lifting is crucial for gathering data regards patient handling. The aim of this study was to consider reliability and validity and re-structure of two special tools for patient handling’s tasks.
Methods
In this cross- sectional study 249 nurses were fully participated. As recommended by literature for cultural adaptation of instruments, forward/backward translation method was applied. Reliability of the translated version was assessed by Cronbach’s alpha coefficient. Validity testing for the two scales was based on content validity index/ratio analysis and also Exploratory Factor Analysis was run to extract latent factors.
Results
Reliability estimated by internal consistency reached a Cronbach’s Alpha of above 0.7 for all subscales of two questionnaires. After testing the validity, the final version of questionnaires was remained by 14 and 15 questions respectively.
Conclusions
These instruments evaluated for manual handling of normal and obese patients had acceptable validity and reliability in Iranian Nursing context. So, these tools can be used in further studies with the same cultures.
Background
Precise causes of musculoskeletal complaints among nurses are not known well, but many studies have pointed to manual patient handling tasks. Subjective judgment and decision-making process for patient lifting is crucial for gathering data regards patient handling. The aim of this study was to consider reliability and validity and re-structure of two special tools for patient handling’s tasks.
Methods
In this cross- sectional study 249 nurses were fully participated. As recommended by literature for cultural adaptation of instruments, forward/backward translation method was applied. Reliability of the translated version was assessed by Cronbach's alpha coefficient. Validity testing for the two scales was based on content validity index/ratio analysis and also Exploratory Factor Analysis was run to extract latent factors.
Results
Reliability estimated by internal consistency reached a Cronbach's Alpha of above 0.7 for all subscales of two questionnaires. After testing the validity, the final version of questionnaires was remained by 14 and 15 questions respectively.
Conclusions
These instruments evaluated for manual handling of normal and obese patients had acceptable validity and reliability in Iranian Nursing context. So these tools can be used in further studies with the same cultures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.