A method for the estimation of time of death (TOD), was evaluated by measuring the melatonin (MT) content of pineal bodies (PBs), sera and urine samples from 85 cadavers. A total of 44 cadavers were investigated in Sapporo (geographical coordinates N 43 degrees 4', E 141 degrees 21') and 41 in Tokyo (N 35 degrees 39', E 139 degrees 44'). MT contents were measured by radioimmunoassay (RIA) in 75 PBs, 27 sera and 14 urine samples. Exponential differences of pineal MT content were recognized between peaks in nighttime and nadirs in daytime, ranging from 0.099 to 63.2 ng/PB. Circadian rhythms were also observed for the concentrations of MT in serum (11-205 pg/ml), and in urine (7.5-137.5 pg/ml). Consequently, criteria for the TOD estimation are proposed as follows. 1) Pineal MT contents--(1) 0-0.2 ng/PB: TOD 1100-1700 hours, (2) 0.2-0.3 ng/PB: TOD 0700-2000 hours, (3) 0.3-1 ng/PB: inconclusive, (4) 1-4 ng/PB: TOD 1600-1000 hours, (5) 4-8 ng/PB: TOD 2000-0800 hours, (6) over 8 ng/PB: TOD 2000-0500 hours, 2) Serum MT concentration--(1) 0-100 pg/ml: inconclusive, (2) over 100 pg/ml: TOD 2200-0100 hours, and 3) Urinary MT concentration--(1) 0-35 pg/ml: inconclusive, (2) over 35 pg/ml: TOD 1800-0600 hours. The range of the estimation can be limited by a combination of these 3 criteria. The present method can be combined with other methods for estimating the TOD to decrease the range.
Sensitivity to amalgam may cause exacerbation of aspirin-intolerant asthma in some patients. To the best of our knowledge, this is the first case report of amalgam allergy associated with aspirin-intolerant asthma.
Monoclonal antibodies(moAbs) reactive with melatonin(MT) were produced using MT, coupled to bovine serum albumin(BSA) with the Mannich reaction, as immunogen and conventional hybridoma techniques. Hybridoma clones secreting the moAbs were selected by an enzyme-linked immunosorbent assay system using MT-carboxymethylchitin and BSA as screening antigens. The moAbs from 6 clones were characterized by a cross-reactivity test using radioimmunoassay with 125I-labelled MT. The moAbs recognized MT but hardly recognized other analogues except for N-acetylserotonin with a crossreactivity of 0.81%. An inhibition curve for MT was obtained in the range of 50 pg to 100 ng and 1.4 ng of MT inhibited the value of the assay by half. There is interference from some unknown source in human serum.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.