Over seven months of follow-up, the clinical and angiographic outcomes were better in patients who received a stent than in those who received standard coronary angioplasty. However, this benefit was achieved at the cost of a significantly higher risk of vascular complications at the access site and a longer hospital stay.
The content of these European Society of Cardiology (ESC) Guidelines has been published for personal and educational use only. No commercial use is authorized. No part of the ESC Guidelines may be translated or reproduced in any form without written permission from the ESC. Permission can be obtained upon submission of a written request to Oxford University Press, the publisher of the European Heart Journal and the party authorized to handle such permissions on behalf of the ESC.
Background-Coronary arteries without focal stenosis at angiography are generally considered non-flow-limiting.However, atherosclerosis is a diffuse process that often remains invisible at angiography. Accordingly, we hypothesized that in patients with coronary artery disease, nonstenotic coronary arteries induce a decrease in pressure along their length due to diffuse coronary atherosclerosis. Methods and Results-Coronary pressure and fractional flow reserve (FFR), as indices of coronary conductance, were obtained from 37 arteries in 10 individuals without atherosclerosis (group I) and from 106 nonstenotic arteries in 62 patients with arteriographic stenoses in another coronary artery (group II). In group I, the pressure gradient between aorta and distal coronary artery was minimal at rest (1Ϯ1 mm Hg) and during maximal hyperemia (3Ϯ3 mm Hg). Corresponding values were significantly larger in group II (5Ϯ4 mm Hg and 10Ϯ8 mm Hg, respectively; both PϽ0.001). The FFR was near unity (0.97Ϯ0.02; range, 0.92 to 1) in group I, indicating no resistance to flow in truly normal coronary arteries, but it was significantly lower (0.89Ϯ0.08; range, 0.69 to 1) in group II, indicating a higher resistance to flow. In 57% of arteries in group II, FFR was lower than the lowest value in group I. In 8% of arteries in group II, FFR was Ͻ0.75, the threshold for inducible ischemia. Conclusion-Diffuse coronary atherosclerosis without focal stenosis at angiography causes a graded, continuous pressure fall along arterial length. This resistance to flow contributes to myocardial ischemia and has consequences for decision-making during percutaneous coronary interventions.
A B S T R A C T The time relationship for recovery of mechanical function, the intramyocardial electrogram and coronary flow after brief periods of regional myocardial ischemia, was studied in conscious dogs. Total left ventricular (LV) function was assessed with measurements of LV systolic and diastolic pressures, rate of change of LV pressure (dP/dt), and dP/dt/P. Regional LV function was assessed with measurements of regional segment length and velocity of shortening. An implanted hydraulic occluder on either the left anterior descending or circumflex coronary artery was inflated for 5-and 15-min periods on separate days. A 5-min occlusion depressed overall LV function transiently, but just before release of occlusion overall function had nearlv returned to control. At this time regional function in the ischemic zone was still depressed to the point of absent shortening or paradoxical motion during systole and was associated with marked ST segment elevation (+ 10± 2.2 mV) at the sites where function was measured. With release of occlusion and reperfusion the intramyocardial electrogram returned to normal within 1 min, and reactive hyperemia subsided by 5-10 min. In contrast to the rapid return to preocclusion levels for coronary flow and the electrogram, regional mechanical function remained depressed for over 3 h. A 15-min coronary occlusion resulted in an even more prolonged (> 6 h)
Fractional flow reserve derived from pressure measurements correlates more closely to relative flow reserve derived from PET than angiographic parameters. This validates in humans the use of fractional flow reserve as an index of the physiological consequences of a given coronary artery stenosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.