Background: To evaluate parameters on the state and trait anxiety scores of patients receiving intravitreal injections. Methods: One hundred thirteen patients were included in the study. All subjects received intravitreal ranibizumab or bevacizumab injections. To measure the level of anxiety, Spielberg's State-Trait Anxiety Inventory questionnaire was used. Results: The mean state anxiety scores were 45.19 ± 5.62 in experienced patients and 43.10 ± 6.62 in inexperienced patients (p = 0.078). The mean trait anxiety scores were 50.14 ± 6.62 in experienced patients and 49.17 ± 10.79 in inexperienced patients (p = 0.810). Additionally, there was no statistically significant difference in the state and trait anxiety scores between the male and female, employed, and retired patients (p > 0.05). Conclusion: Anxiety may not show significant differences according to sociodemographic status. High anxiety scores found in this study also emphasize that health care providers should try to decrease anxiety levels during the course of treatment.
We report the ocular manifestations of Alport syndrome and the surgical results in 4 patients. All 4 patients had anterior lenticonus; 2 also had posterior lenticonus in both eyes, 3 had flecked retina, and 1 had posterior polymorphous dystrophy. In both eyes of the 4 patients, phacoemulsification with intraocular lens (IOL) implantation was performed to treat anterior and posterior lenticonus. The postoperative visual acuity was excellent in all patients. We recommend phacoemulsification with IOL implantation as a safe and effective procedure in patients with lenticonus secondary to Alport syndrome.
Purpose: To report the efficacy of intravitreal dexamethasone implant in a patient with retinitis pigmentosa and bilateral cystoid macular edema unresponsive to topical carbonic anhydrase inhibitors. Case Report: A 36-year-old man with bilateral cystoid macular edema associated with retinitis pigmentosa that was unresponsive to topical carbonic anhydrase inhibitors underwent bilateral 0.7-mg intravitreal dexamethasone implants two weeks apart. Spectral domain optical coherence tomography revealed resolution of macular edema one week following each injection in both eyes and his visual acuity improved. However, macular edema recurred two months later in OS and three months later in OD. Second implant was considered for both eyes. No implant-related complication was experienced during the follow-up of seven months. Conclusion: Inflammatory process seems to play a role in retinitis pigmentosa. Intravitreal dexamethasone implant may offer retina specialists a therapeutic option especially in cases unresponsive to other treatment regimens in eyes with retinitis pigmentosa-related macular edema.
Corneal viscoelastic properties are not significantly influenced in the late postoperative period by 23-G TSV which is a minimal invasive vitreoretinal surgical technique.
Background: To evaluate the agreement between the optic nerve head (ONH) measurements obtained by spectral-domain optical coherence tomography/scanning laser ophthalmoscope (SD-OCT/SLO) and the Heidelberg retinal tomograph III (HRT-III), and to compare the ONH measurements of both devices in different glaucoma types. Methods: In a prospective study, 30 patients with primary open-angle glaucoma (POAG) and 30 patients with pseudoexfoliation glaucoma (PXG) were enrolled. All patients underwent SD-OCT/SLO and HRT-III evaluation of the ONH during the same visit. Agreement between measurements of SD-OCT/SLO and HRT-III were evaluated by determination of intraclass correlation coeficients. In addition, mean ONH measurements obtained with both devices were compared between POAG and PXG patient groups. Results: Mean SD-OCT/SLO measurements were greater than those of HRT-III, except for mean and maximum cup depth. Intraclass correlation coefficient values for disc area, rim area, cup area, cup/disc area ratio, mean cup depth and maximum cup depth were 0.367, 0.213, 0.632, 0.681, 0.775 and 0.661, respectively. No significant differences were found between ONH parameters of POAG and PXG patients as measured with both devices (p > 0.01). Conclusion: ONH measurements with SD-OCT/SLO and HRT-III did not show clinically acceptable agreement in glaucoma patients. This precludes interchangeable use of these measurements in clinical practice. PXG and POAG patient groups displayed similar ONH measurements with both devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.