Hand loss is a highly disabling event that markedly affects the quality of life. To achieve a close to natural replacement for the lost hand, the user should be provided with the rich sensations that we naturally perceive when grasping or manipulating an object. Ideal bidirectional hand prostheses should involve both a reliable decoding of the user's intentions and the delivery of nearly "natural" sensory feedback through remnant afferent pathways, simultaneously and in real time. However, current hand prostheses fail to achieve these requirements, particularly because they lack any sensory feedback. We show that by stimulating the median and ulnar nerve fascicles using transversal multichannel intrafascicular electrodes, according to the information provided by the artificial sensors from a hand prosthesis, physiologically appropriate (near-natural) sensory information can be provided to an amputee during the real-time decoding of different grasping tasks to control a dexterous hand prosthesis. This feedback enabled the participant to effectively modulate the grasping force of the prosthesis with no visual or auditory feedback. Three different force levels were distinguished and consistently used by the subject. The results also demonstrate that a high complexity of perception can be obtained, allowing the subject to identify the stiffness and shape of three different objects by exploiting different characteristics of the elicited sensations. This approach could improve the efficacy and "life-like" quality of hand prostheses, resulting in a keystone strategy for the near-natural replacement of missing hands.
Highlights d Biomimetic hybrid sensory encodings are perceived as highly natural d Biomimetic hybrid sensory encodings restore rich tactile sensitivity d Biomimetic hybrid sensory encodings improve manual dexterity and accuracy d Biomimetic hybrid sensory encodings enhance prosthesis embodiment
Background: Chemotherapy-induced peripheral neuropathy (CIPN) is a debilitating and dose-limiting complication of cancer treatment. Thus far, the impact of CIPN has not been studied in a systematic clinimetric manner. The objective of the study was to select outcome measures for CIPN evaluation and to establish their validity and reproducibility in a cross-sectional multicenter study. Patients and methods:After literature review and a consensus meeting among experts, face/content validity were obtained for the following selected scales: the National Cancer Institute-Common Toxicity Criteria (NCI-CTC), the Total Neuropathy Score clinical version (TNSc), the modified Inflammatory Neuropathy Cause and Treatment (INCAT) group sensory sumscore (mISS), the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30, and CIPN20 quality-of-life measures. A total of 281 patients with stable CIPN were examined. Validity (correlation) and reliability studies were carried out.Results: Good inter-/intra-observer scores were obtained for the TNSc, mISS, and NCI-CTC sensory/motor subscales. Test-retest values were also good for the EORTC QLQ-C30 and CIPN20. Acceptable validity scores were obtained through the correlation among the measures. Conclusion:Good validity and reliability scores were demonstrated for the set of selected impairment and quality-of-life outcome measures in CIPN. Future studies are planned to investigate the responsiveness aspects of these measures.
Current myoelectric prostheses allow transradial amputees to regain voluntary motor control of their artificial limb by exploiting residual muscle function in the forearm. However, the overreliance on visual cues resulting from a lack of sensory feedback is a common complaint. Recently, several groups have provided tactile feedback in upper limb amputees using implanted electrodes, surface nerve stimulation, or sensory substitution. These approaches have led to improved function and prosthesis embodiment. Nevertheless, the provided information remains limited to a subset of the rich sensory cues available to healthy individuals. More specifically, proprioception, the sense of limb position and movement, is predominantly absent from current systems. Here, we show that sensory substitution based on intraneural stimulation can deliver position feedback in real time and in conjunction with somatotopic tactile feedback. This approach allowed two transradial amputees to regain high and close-to-natural remapped proprioceptive acuity, with a median joint angle reproduction precision of 9.1° and a median threshold to detection of passive movements of 9.5°, which was comparable with results obtained in healthy participants. The simultaneous delivery of position information and somatotopic tactile feedback allowed both amputees to discriminate the size and compliance of four objects with high levels of performance (75.5%). These results demonstrate that tactile information delivered via somatotopic neural stimulation and position information delivered via sensory substitution can be exploited simultaneously and efficiently by transradial amputees. This study paves a way to more sophisticated bidirectional bionic limbs conveying richer, multimodal sensations.
Objective: Hand amputation is a highly disabling event, which significantly affects quality of life. An effective hand replacement can be achieved if the user, in addition to motor functions, is provided with the sensations that are naturally perceived while grasping and moving. Intraneural peripheral electrodes have shown promising results toward the restoration of the sense of touch. However, the long-term usability and clinical relevance of intraneural sensory feedback have not yet been clearly demonstrated. Methods: To this aim, we performed a six months clinical study with three trans-radial amputees who received implants of transverse intrafascicular multichannel electrodes (TIMEs) in their median and ulnar nerves. After calibration, electrical stimulation was delivered through the TIMEs connected to artificial sensors in the digits of a prosthesis to generate sensory feedback, which was then used by the subjects while performing different grasping tasks. Results: All the subjects, notwithstanding their important clinical differences, reported stimulationinduced sensations from the phantom hand for the whole duration of the trial. They also successfully integrated the sensory feedback into their motor control strategies while performing experimental tests simulating tasks of real life (with and without the support of vision). Finally, they reported a decrement of their phantom limb pain and a general improvement in mood state. Interpretation: The promising results achieved with all subjects show the feasibility of the use of intraneural stimulation in clinical settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.