The dielectric properties of gray matter in the frequency range of 800-2450 MHz were measured on 20 human brains immediately after excision, less than 10 h after death. The brains were obtained during autopsy of 10 male and 10 female humans who died at ages between 47.5 and 87.5 years [70.4 +/- 9.8 years, mean +/- standard deviation (SD)]. The tissue temperature at the measurement sites ranged between 18 and 25 degrees C (21.35 +/- 1.6 degrees C, mean +/- SD). On each brain, four specific locations on the temporal lobe were measured on the right and left sides, i.e., 160 different measurements of the dielectric properties were performed. The dielectric probe was placed on the intact arachnoid on a gyrus in the selected area. The measurements yielded a mean value (+/-SD) of gray matter equivalent conductivity of 1.13 +/- 0.12 and 2.09 +/- 0.16 S/m at 800 and 2450 MHz, respectively. The mean value of measured relative permittivity was 58.2 +/- 3.3 and 54.7 +/- 3.3 at 800 and 2450 MHz, respectively. Taking into account a positive temperature coefficient of equivalent conductivity, these measurements indicate that the equivalent conductivity of human gray matter at body temperature is somewhat higher than today's generally accepted value, which is based on measurements on animal tissue and excised samples of human tissue measured more than 24 h postmortem.
Ten experiments on pigs were performed to investigate possible postmortem changes of the dielectric properties of brain gray matter in the frequency range of 800-1900 MHz. After keeping the animals in stable anaesthesia for at least 45 min, they were euthanatised by an intravenous injection of hypertonic potassium chloride (KCl), causing cardiac arrest within 3 min. Measurements of the dielectric properties were performed repeatedly from at least 45 min prior to death to 18 h after euthanasia. The anaesthesia regimen was chosen to minimize influence on brain tissue characteristics such as brain water content, intracranial blood volume, and cerebral blood flow. The data showed a decline of mean gray matter equivalent conductivity of about 15% at 900 MHz and about 11% at 1800 MHz within the first hour after death. The decline in permittivity was less pronounced (about 3-4%) and almost frequency independent. The results indicate that in vitro measurements of dielectric properties of brain tissue underestimate equivalent conductivity as well as permittivity of living tissue. These changes may affect the generally accepted data of dielectric properties of brain tissue widely used in RF dosimetry.
In recent years several studies regarding possible effects of radio frequency (RF) electromagnetic fields (EMFs) on cognitive brain function were reported. In many of these studies on awake humans the working tasks were presented visually to the test subjects, e.g., on a computer screen. Therefore, the question of where in the chain of visual perception, brain processing and response a possible effect could be induced seems to be of interest. In this study, possible effects of exposure to a generic 1.97 GHz UMTS-like signal on human visual perception were investigated in a double blinded, crossover study including 58 healthy volunteer subjects (29 male, 29 female), aged 29 +/- 5.1 years (mean +/- SD). Each test subject underwent a battery of four different clinical tests three times (two different exposure levels and sham exposure) to assess selected parameters of visual perception. The generic signals applied to the subjects' head represented the RF emissions of an UMTS mobile phone under constant receiving conditions and the under condition of strongly varying transmit power, i.e., the signal envelope contained low frequency components. In the high exposure condition the resulting average exposure of the test subjects in the cortex of the left temporal lobe of the brain was 0.63 W/kg (1 g averaged SAR) and 0.37 W/kg (10 g averaged SAR). Low exposure condition was one tenth of high exposure and sham was at least 50 dB (corresponding to a factor of 100,000) below low exposure. Statistical evaluation of the obtained test results revealed no statistically significant differences in the investigated parameters of visual perception between the exposure conditions and sham exposure.
Based on numerical computations using commercially available finite difference time domain code and a state-of-the art anatomical model of a 5-year old child, the influence of skin conductivity on the induced electric field strength inside the tissue for homogeneous front-to-back magnetic field exposure and homogeneous vertical electric field exposure was computed. Both ungrounded as well as grounded conditions of the body model were considered. For electric field strengths induced inside CNS tissue the impact of skin conductivity was found to be less than 15%. However, the results demonstrated that the use of skin conductivity values as obtainable from the most widely used data base of dielectric tissue properties and recommended by safety standards are not suitable for exposure assessment with respect to peripheral nerve tissue according to the ICNIRP 2010 guidelines in which the use of the induced electric field strengths inside the skin is suggested as a conservative surrogate for peripheral nerve exposure. This is due to the fact that the skin conductivity values derived from these data bases refer to the stratum corneum, the uppermost layer of the skin, which does not contain any nerve or receptor cells to be protected from stimulation effects. Using these skin conductivity values which are approximately a factor 250-500 lower than skin conductivity values used in studies on which the ICNIRP 2010 guidelines are based on, may lead to overestimations of the induced electric field strengths inside the skin by substantially more than a factor of 10. However, reliable conductivity data of deeper skin layers where nerve and preceptor cells are located is very limited. It is therefore recommended to include appropriate background information in the ICNIRP guidelines and the dielectric tissue property databases, and to put some emphasis on a detailed layer-specific characterization of skin conductivity in near future.
Several studies in the past reported influences of electromagnetic emissions of GSM phones on reaction time in humans. However, there are currently only a few studies available dealing with possible effects of the electromagnetic fields emitted by UMTS mobile phones. In our study, 40 healthy volunteers (20 female, 20 male), aged 26.0 years (range 21-30 years) underwent four different computer tests measuring reaction time and attention under three different UMTS mobile phone-like exposure conditions (two exposure levels plus sham exposure). Exposure of the subjects was accomplished by small helical antennas operated close to the head and fed by a generic signal representing the emissions of a UMTS mobile phone under constant receiving conditions as well as under a condition of strongly varying transmit power. In the high exposure condition the resulting peak spatial average exposure of the test subjects in the cortex of the left temporal lobe of the brain was 0.63 W/kg (min. 0.25 W/kg, max. 1.49 W/kg) in terms of 1 g averaged SAR and 0.37 W/kg (min. 0.16 W/kg, max. 0.84 W/kg) in terms of 10 g averaged SAR, respectively. Low exposure condition was one-tenth of high exposure and sham was at least 50 dB below low exposure. Statistical analysis of the obtained test parameters showed that exposure to the generic UMTS signal had no statistically significant immediate effect on attention or reaction. Therefore, this study does not provide any evidence that exposure of UMTS mobiles interferes with attention under short-term exposure conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.