Abstract. Chronic hepatitis B virus (HBV) infection is a worldwide problem and HBV reactivation following anticancer chemotherapy has become an emerging clinical challenge. However, the mechanisms of HBV reactivation following chemotherapy remain unclear. Epirubicin is an anthracycline drug used in chemotherapy to treat numerous types of malignancy, including breast cancer, acute leukemia, malignant lymphoma, lung cancer, ovarian cancer and stomach cancer. Epirubicin acts by intercalating DNA strands and inhibiting DNA and RNA synthesis. In this study, it was demonstrated that epirubicin directly upregulated the levels of in vitro HBV replication in a concentration-dependent manner. Exposure to epirubicin for 24 h induced >11-and 6-fold increases in the levels of intracellular and secreted HBV DNA, respectively. In concordance with the elevated levels of HBV DNA, the expression levels of HBV pregenomic RNA, intracellular HBV surface and HBV core antigens, and secreted HBV e antigen were significantly increased by treatment with 0.5 µM epirubicin. Notably, epirubicin promoted cellular excretion of HBV nucleocapsids, which are closely associated with the pathological effects of HBV, including acute liver failure. In conclusion, epirubicin exhibited a direct stimulatory effect on HBV replication and this may be a novel mechanism of HBV reactivation following cytotoxic anticancer chemotherapy.
ObjectiveTo determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging.Materials and MethodsThis study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test.ResultsMean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A.ConclusionNon-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.