A new strategy to yield information from the maximum number of voxels, each at the optimum signal-to-noise ratio (SNR) per unit time, in MR spectroscopic imaging (MRSI) is introduced. In the past, maximum acquisition duty-cycle was obtained by multiplexing in time several single slices each repetition time (TR), while optimal SNR was achieved by encoding the entire volume of interest (VOI) each TR. We show that optimal SNR and acquisition efficiency can both be achieved simultaneously by multiplexing in space and time several slabs of several slices, each. Since coverage of common VOIs in 3D proton MRSI in the human brain typically requires eight or more slices, at 3 T or higher magnetic fields, two or more slabs can fit into the optimum TR (ϳ1.6 s). Since metabolite concentrations in the brain are lower than tissue water by orders of magnitude, magnetic resonance spectroscopy (MRS) has been beset by inferior signal-to-noise ratio (SNR) per unit time compared to MRI. To partially compensate for this, MRS voxels are typically more than ϫ10 3 larger (cm 3 vs. mm 3 ), and acquisition times are ϫ10 2 -10 3 longer (many minutes vs. a few seconds) than MRI (1). It is not surprising, therefore, that substantial technical and methodological efforts have been made to improve the SNR and reduce the acquisition time of MRS, especially its most prevalent proton ( 1 H) variants. These efforts have progressed along two main paths. The first method involved multiplexing in space, i.e., increasing the spatial coverage from a single-to a simultaneous multivoxel acquisition (2,3). This technique (see Fig. 1a), which is known as MRS imaging (MRSI) and was first described for 1 H by Luyten et al. (4), yields much more spatial information at equal SNR (5), as determined by the voxel size and acquisition time (6). To reduce SNR loss from incomplete longitudinal relaxation, T 1 , the TR is extended beyond the actual acquisition-cycle, T C , the time needed to prepare and acquire one transient, as determined primarily by the desired spectral resolution. Since the system "recovers" for (TR-T C ), its duty cycle (DC) is an inherently suboptimal Ͻ100%. The second approach, introduced for 1 H-MRSI by Duyn and Moonen (7), was to maximize the amount of information per unit time by increasing the DC. This was achieved by multiplexing in time, acquiring several T C 's every TR, each from a different slice, as shown in Fig. 1b (8). The problem with this approach is that in order to satisfy spatial coverage and spectral resolution requirements, TR must be longer than the optimum, TR opt , and consequently the SNR is suboptimal.In this paper we extend the approach of 3D-multislab MRI (9) to 1 H-MRSI by multiplexing in space and time, as shown in Fig. 1c, and derive expressions for its gains in the DC and SNR over the current state of the art. We demonstrate that when more than one T C fits into TR opt , slab interleaving is more efficient than either the multislice approach (7) or whole volume of interest (VOI) per TR opt coverage (2,3,10 -15). W...
While brain imaging studies emphasized the category selectivity of face-related areas, the underlying mechanisms of our remarkable ability to discriminate between different faces are less understood. Here, we recorded intracranial local field potentials from face-related areas in patients presented with images of faces and objects. A highly significant exemplar tuning within the category of faces was observed in high-Gamma (80-150 Hz) responses. The robustness of this effect was supported by single-trial decoding of face exemplars using a minimal (n = 5) training set. Importantly, exemplar tuning reflected the psychophysical distance between faces but not their low-level features. Our results reveal a neuronal substrate for the establishment of perceptual distance among faces in the human brain. They further imply that face neurons are anatomically grouped according to well-defined functional principles, such as perceptual similarity.
We report acquisition of 3D image-guided localized proton spectroscopy (1H-MRS) in the human brain on a standard clinical imager. 3D coverage is achieved with a hybrid of chemical shift imaging (CSI) and transverse Hadamard spectroscopic imaging (HSI). 16 x 16 x 4 arrays of 3.5 and 1 ml voxels were obtained in 27 min. The spatially selective HSI 90 degrees pulses incorporate naturally into a PRESS double spin-echo sequence to subdivide the VOI into four partitions along its short axis. 2D CSI (16 x 16) is performed along the other long axes. Because the hybrid excites the spins in the entire VOI, a square-root-N signal-to-noise-ratio (SNR) gain per given examination time is realized compared with sequentially interleaving N 2D slices. A two-fold gain in sensitivity is demonstrated in the brain for N = 4.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.