Purpose To evaluate the follow up and treatment outcome of central serous chorioretinopathy (CSCR) based on the new multimodal imaging-based classification and identify the predictors for anatomic and visual outcome. Methods Retrospective, multicentric study on 95 eyes diagnosed with CSCR and a follow up of at least 12 months were included. Eyes with macular neovascularization, atypical CSCR or any other disease were excluded. Results At the baseline, observation was advised to 70% eyes with simple CSCR whereas photodynamic therapy (PDT) was performed in 49% eyes with complex CSCR. Over the follow up, decrease in CMT was significantly higher in simple CSCR as compared to complex CSCR ( P = 0.008) and the recurrences were significantly more in eyes with lower CMT at baseline ( P = 0.0002). Median time of resolution of SRF was 3 months and 6 months in simple and complex CSCR respectively ( P = 0.09). For the 12 months follow up, the median fluid free period was greater ( P = 0.03) while number of interventions performed was lesser in eyes with simple CSCR as compared to complex CSCR ( P = 0.006). Multiple regression analysis showed baseline best corrected visual acuity (BCVA) and baseline persistent SRF to be significantly predictive of BCVA and persistent SRF at 12 months ( P < 0.0001, 0.04) respectively. Conclusions Complex CSCR more often required PDT, was associated with shorter fluid free interval and longer time for SRF resolution. Baseline BCVA and persistent SRF were predictive of final visual and anatomical outcome. The new multimodal imaging based classification is helpful in establishing objective criteria for planning treatment approaches for CSCR.
Background: To map the choroidal vascularity index and compare two eyes in patients with unilateral central serous chorioretinopathy (CSCR). Methods: This was a retrospective, observational study performed in patients with unilateral CSCR. Choroidal thickness (CT) and Choroidal vascularity index (CVI) were measured and mapped in various zones according to the early treatment diabetic retinopathy (ETDRS) grid. Results: A total of 20 CSCR patients (20 study and 20 fellow eyes) were included in the study. Outer nasal region CT was seen to be significantly lower than central CT (p = 0.042) and inner nasal CT (p = 0.007); outer ring CT was significantly less than central (p = 0.04) and inner ring (p = 0.01) CT in CSCR eyes. On potting all the CVI values against the corresponding CT values, a positive correlation was seen in CSCR eyes (r = 0.54, p < 0.01), which was slightly weaker in fellow eyes (r = 0.3, p < 0.01) and a negative correlation was seen in healthy eyes (r = −0.262, p < 0.01). Conclusions: Correlation between CVI and CT was altered in CSCR eyes as compared to fellow and normal eyes with increasing CVI towards the center of the macula and superiorly in CSCR eyes.
Background
Despite the XEN gel stent low-risk profile, various complications following the implant have been described, including internal and external occlusion, with a consequent postoperative rise in intraocular pressure (IOP). In this case report we aimed to present a XEN45 stent internal occlusion successfully treated by trimming in situ its proximal end with a 25 G vitreous scissors using a bimanual technique.
Case presentation
A 63-year-old male patient affected by primary open angle glaucoma (IOP = 25 mmHg) and a full thickness macular hole in his right eye, underwent ab-interno Xen gel stent implantation and, 1 month later, a 25 G vitrectomy surgery. Despite a significant IOP reduction after stent implant, 6 days after vitrectomy, IOP increased (25 mmHg) and the conjunctival bleb flattened following occlusion of stent internal ostium by a clot of presumed fibrinous material. The Nd:YAG laser failed to remove the clot, so that we decided to snip a small bit of the proximal end of the Xen tube (about 0,5 mm length) with a 25 G vitreous scissors, using a bimanual technique. In the postoperative day 1 and month 1, the IOP was 8 mmHg and 12 mmHg, respectively. The Anterior Segment OCT confirmed a functional, layered, filtering bleb, and the normal appearance and patency of the XEN proximal segment. No side effects from the intervention were observed.
Conclusions
Ab interno trimming with vitreous scissors of the occluded proximal end of the XEN stent may represent a safe, rapid and efficient method to restore aqueous humor subconjunctival drainage.
scite is a Brooklyn-based startup that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.