Objectives: Although infantile hypertrophic pyloric stenosis (IHPS) is a well-known disease, there is no systematic review regarding the optimal diagnostic strategy. We conducted a systematic review and meta-analysis to obtain diagnostic accuracy of all methods to diagnose IHPS. Methods: According to the PRISMA guidelines we searched MEDLINE and Embase to identify studies reporting sensitivity and specificity of all methods used to diagnose IHPS. Inclusion criteria were infants with suspicion of/or diagnosed with IHPS who underwent pyloromyotomy or had clinical follow-up. A random-effects model was used to obtain pooled estimates of sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Results: After screening 5364 studies, we included 43 studies with in total 6085 infants (n = 4241 IHPS; n = 1844 controls). The diagnostic sensitivity of palpation ranged from 10.0–93.4% and decreased over time. Different parameters for ultrasonography were found. Most used parameters were pyloric muscle thickness (PMT) ≥ 3 mm (pooled sensitivity 97.6% and specificity 98.8%), PMT ≥ 4 mm (pooled sensitivity 94.0% and specificity 98.0%) or a combination of PMT ≥ 4 mm and/or pyloric canal length (PCL) ≥16 mm (pooled sensitivity 94.0% and specificity 91.7%). The AUC showed high diagnostic accuracy (0.997, 0.966 and 0.981 respectively), but large heterogeneity exists. Due to the large differences in cut-off values no meta-analysis could be conducted for pyloric canal length (PCL) and pyloric diameter (PD). Conclusions: Palpation has limited sensitivity in diagnosing IHPS. We showed that ultrasonography has highest diagnostic accuracy to diagnose IHPS and we advise to use PMT ≥ 3 mm as cut-off. Advances in knowledge: This is the first systematic review and meta-analysis on diagnosing IHPS, which summarizes the available literature and may be used as a guideline.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.