The non-uniform distribution of atherosclerosis within the arterial system has been attributed to pro-atherogenic influences of low, oscillatory haemodynamic wall shear stress (WSS) on endothelial cells (EC). This theory is challenged by the changes in lesion location that occur with age in human and rabbit aortas. Furthermore, a number of point-wise comparisons of lesion prevalence and WSS have failed to support it. Here we investigate the hypothesis that multidirectional flow—characterized as the average magnitude of WSS components acting transversely to the mean vector (transWSS)—plays a key role. Maps of lesion prevalence around aortic branch ostia in immature and mature rabbits were compared with equivalent maps of time average WSS, the OSI (an index characterizing oscillatory flow) and transWSS, obtained from computational simulations; Spearman’s rank correlation coefficients were calculated for aggregated data and 95% confidence intervals were obtained by bootstrapping methods. Lesion prevalence correlated positively, strongly and significantly with transWSS at both ages. Correlations of lesion prevalence with the other shear metrics were not significant or were significantly lower than those obtained for transWSS. No correlation supported the low, oscillatory WSS theory. The data are consistent with the view that multidirectional near-wall flow is highly pro-atherogenic. Effects of multidirectional flow on EC, and methods for investigating them, are reviewed. The finding that oscillatory flow has pro-inflammatory effects when acting perpendicularly to the long axis of EC but anti-inflammatory effects when acting parallel to it may explain the stronger correlation of lesion prevalence with transWSS than with the OSI.
he lymphatic system plays an important role in human circulatory and immune homeostasis. Peripheral lymph nodes (LNs) are regional hubs that receive interstitial fluid as well as circulating blood. They contain large numbers of immune cells and the complex internal architecture of LNs constitutes an interface between the cellular and molecular constituents of lymph and blood. Cellular debris is filtered and primary immune responses can be generated in LNs to pathogens (1). LN blood vessels are highly specialized for facilitating T-cell entry to the node (2). The spatial distribution of surface area for exchange of fluid with blood vessels in LNs determines the amount of local fluid movement, and it is therefore important to quantify the three-dimensional distribution of LN blood vessels. In patients with cancer, tumor cells can also traffic through lymphatic channels to regional LNs (3). Recent studies have demonstrated that metastatic cells migrate toward and into LN blood vessels (4,5). Malignant processes are associated with both angiogenesis and lymphangiogenesis (6). LNs may even act as a permissive niche to support the proliferation of metastatic cells and promote movement to distant sites (7). The accurate identification and quantification of metastatic LNs remains essential for prognosis and treatment planning (8).
Objective -The distribution of atherosclerotic lesions changes with age in human and rabbit aortas. We investigated if this can be explained by changes in patterns of blood flow and wall shear stress. Methods -The luminal geometry of thoracic aortas from immature and mature rabbits was obtained by micro-CT of vascular corrosion casts. Blood flow was computed and average maps of wall shear stress were derived. Results -The branch anatomy of the aortic arch varied widely between animals. Wall shear was increased downstream and to a lesser extent upstream of intercostal branch ostia, and a stripe of high shear was located on the dorsal descending aortic wall. The stripe was associated with two vortices generated by aortic arch curvature; their persistence into the descending aorta depended on aortic taper and was more pronounced in mature geometries. These results were not sensitive to the modelling assumptions.Conclusions -Blood flow characteristics in the rabbit aorta were affected by the degree of taper, which tends to increase with age in the aortic arch and strengthens secondary flows into the descending aorta. Previouslyobserved lesion distributions correlated better with high than low shear, and age-related changes around branch ostia were not explained by the flow patterns.
Effects of fluid dynamics on cells are often studied by growing the cells on the base of cylindrical wells or dishes that are swirled on the horizontal platform of an orbital shaker.The swirling culture medium applies a shear stress to the cells that varies in magnitude and directionality from the center to the edge of the vessel. Computational fluid dynamics methods are used to simulate the flow and hence calculate shear stresses at the base of the well. The shear characteristics at each radial location are then compared with cell behavior at the same position. Previous simulations have generally ignored effects of surface tension and wetting, and results have only occasionally been experimentally validated. We investigated whether such idealized simulations are sufficiently accurate, examining a commonly-used swirling well configuration. The breaking wave predicted by earlier simulations was not seen, and the edge-to-center difference in shear magnitude (but not directionality) almost disappeared, when surface tension and wetting were included. Optical measurements of fluid height and velocity agreed well only with the computational model that incorporated surface tension and wetting. These results demonstrate the importance of including accurate fluid properties in computational models of the swirling well method.
Abnormal blood flow and wall shear stress (WSS) can cause and be caused by cardiovascular disease. To date, however, no standard method has been established for mapping WSS in vivo. Here we demonstrate wide-field assessment of WSS in the rabbit abdominal aorta using contrast-enhanced ultrasound image velocimetry (UIV). Flow and WSS measurements were made independent of beam angle, curvature or branching. Measurements were validated in an in silico model of the rabbit thoracic aorta with moving walls and pulsatile flow. Mean errors over a cardiac cycle for velocity and WSS were 0.34 and 1.69%, respectively. In vivo time average WSS in a straight segment of the suprarenal aorta correlated highly with simulations (PC = 0.99) with a mean deviation of 0.29 Pa or 5.16%. To assess fundamental plausibility of the measurement, UIV WSS was compared to an analytic approximation derived from the Poiseuille equation; the discrepancy was 17%.Mapping of WSS was also demonstrated in regions of arterial branching. High time average WSS (TAWSS xz = 3.4 Pa) and oscillatory flow (OSI xz = 0.3) were observed near the origin of conduit arteries. In conclusion, we have demonstrated that contrast-enhanced UIV is capable of measuring spatiotemporal variation in flow velocity, arterial wall location and hence WSS in vivo with high accuracy over a large field of view.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.