To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).
To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperative binocular vision-related complaints. Most diplopia-related visual complaints, irrespective of the surgical procedure, were in fact misdiagnosed preoperative disorders. The preoperative evaluation of patients seeking spectacle/contact lens independence should include a complete binocular and accommodation assessment where parameters such as the phoric posture, accommodative amplitude and facility, near point of convergence, fusional reserves and accommodative convergence/accommodation coefficient are measured. This would allow the identification of risk factors that could compromise the success of the refractive surgery and cause clinical symptoms.
Purpose In the event that any ocular parameter involved in the calculation of intraocular lens power could not be properly measured in one eye, it is important to know whether clinically relevant differences between both eyes can be expected. The aim of this work is to evaluate the symmetry of interocular biometric parameters. Methods This was a prospective, cross-sectional study involving 4090 subjects. Patients underwent consecutive swept-source optical biometry performed with an IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The biometric parameters that were evaluated were: axial length (AL), mean anterior curvature (Rm), anterior chamber depth (ACD), crystalline lens thickness (LT), central corneal thickness (CCT) and white-to-white (WTW). The Chang–Waring chord distance (CWC-D) and the Chang–Waring chord angle (CWC-A) were also evaluated. Results There is an excellent correlation between both eyes for almost all the biometric parameters under study, with the exception of the CWC. Agreement for AL was better for eyes shorter than 24 mm. The linearity of the OD-vs-OS relationship can be correctly assumed for all parameters (Cusum test: p > 0.05 in all cases). Conclusion There are no clinically significant interocular differences for the biometric parameters under study, although for all of them, except the LT, statistically significant differences did arise. In the case of AL, moderate differences can be expected in eyes larger than 24 mm.
The aim was to evaluate accommodative and binocular function of phakic intraocular lens implantable collamer lens (ICL) in high and low-to-moderate myopia. Prospective comparative cohort study with 38 myopic patients who underwent ICL implantation were divided into two groups of 19 patients, each one based on the spherical equivalent (SE): high-power (SE ≤ −6 D) and low-to-moderate (SE > −6 D). The push-up amplitude of accommodation (AA), monocular accommodative facility (MAF), distance and near ocular deviation, near convergence amplitude, near point convergence (NPC), stereopsis, and accommodative convergence/accommodation (AC/A) ratio were assessed before surgery and 1 week and 1 month postoperatively. The mean residual refractive error at 1 month after surgery improved in both groups, 0.18 ± 0.34 D and 0.09 ± 0.26 D, respectively (p < 0.001). There was a significant decrease in AA in both groups between preoperatively and at 1-week (p = 0.001; p = 0.008, respectively) and 1-month follow-up (p = 0.001; p = 0.008). For the rest of the binocular measurements, no statistically significant postoperative changes were found in any group. This finding suggests follow-up studies on amplitude of accommodation in phakic intraocular lens ICL implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.