Electrochemical techniques, such as electrochemical impedance spectroscopy (EIS), are widely used for corrosion studies. However, their applicability to studies on metallic cultural heritage has been less spread due to the usual need of performing measurements in-situ on sculptures or monuments. This paper presents the development of a gel polymer electrolyte (G-PE) cell to overcome the difficulties associated with the use of liquid electrolytes for in-situ measurements. 5% agar has been employed to gelify a 0.3 M NaCl electrolyte. Laboratory comparison has demonstrated that gelification with agar does not affect EIS results in a significant way. A robust and convenient electrochemical cell has been fabricated using this G-PE and has been successfully applied to obtain EIS data from a bronze sculpture in the National Archaeological Museum in Madrid (Spain).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.