BackgroundHIV-1 superinfection occurs at varying frequencies in different at risk populations. Though seroincidence is decreased, in the negative partner of HIV-discordant couples after joint testing and counseling in the Zambia Emory HIV Research Project (ZEHRP) cohort, the annual infection rate remains relatively high at 7-8%. Based on sequencing within the gp41 region of each partner's virus, 24% of new infections between 2004 and 2008 were the result of transmission from a non-spousal partner. Since these seroconvertors and their spouses have disparate epidemiologically-unlinked viruses, there is a risk of superinfection within the marriage. We have, therefore, investigated the incidence and viral origin of superinfection in these couples.ResultsSuperinfection was detected by heteroduplex mobility assay (HMA), degenerate base counting of the gp41 sequence, or by phylogenetic analysis of the longitudinal sequences. It was confirmed by full-length env single genome amplification and phylogenetic analysis. In 22 couples (44 individuals), followed for up to five years, three of the newly infected (initially HIV uninfected) partners became superinfected. In each case superinfection occurred during the first 12 months following initial infection of the negative partner, and in each case the superinfecting virus was derived from a non-spousal partner. In addition, one probable case of intra-couple HIV-1 superinfection was observed in a chronically infected partner at the time of his seroconverting spouse's initial viremia. Extensive recombination within the env gene was observed following superinfection.ConclusionsIn this subtype-C discordant couple cohort, superinfection, during the first year after HIV-1 infection of the previously negative partner, occurred at a rate similar to primary infection (13.6% [95% CI 5.2-34.8] vs 7.8% [7.1-8.6]). While limited intra-couple superinfection may in part reflect continued condom usage within couples, this and our lack of detecting newly superinfected individuals after one year of primary infection raise the possibility that immunological resistance to intra-subtype superinfection may develop over time in subtype C infected individuals.
BackgroundThe potential role of antibodies in protection against intra-subtype HIV-1 superinfection remains to be understood. We compared the early neutralizing antibody (NAb) responses in three individuals, who were superinfected within one year of primary infection, to ten matched non-superinfected controls from a Zambian cohort of subtype C transmission cases. Sequence analysis of single genome amplified full-length envs from a previous study showed limited diversification in the individuals who became superinfected with the same HIV-1 subtype within year one post-seroconversion. We hypothesized that this reflected a blunted NAb response, which may have made these individuals more susceptible to superinfection.ResultsNeutralization assays showed that autologous plasma NAb responses to the earliest, and in some cases transmitted/founder, virus were delayed and had low to undetectable titers in all three superinfected individuals prior to superinfection. In contrast, NAbs with a median IC50 titer of 1896 were detected as early as three months post-seroconversion in non-superinfected controls. Early plasma NAbs in all subjects showed limited but variable levels of heterologous neutralization breadth. Superinfected individuals also exhibited a trend toward lower levels of gp120- and V1V2-specific IgG binding antibodies but higher gp120-specific plasma IgA binding antibodies.ConclusionsThese data suggest that the lack of development of IgG antibodies, as reflected in autologous NAbs as well as gp120 and V1V2 binding antibodies to the primary infection virus, combined with potentially competing, non-protective IgA antibodies, may increase susceptibility to superinfection in the context of settings where a single HIV-1 subtype predominates.
Nucleic acid amplification tests for Mycobacterium tuberculosis (MTB) detection from sputum are highly sensitive and specific with smear microscopy positive specimens, but their sensitivity with smear-negative/culture-positive specimens is much lower; therefore, these tests cannot rule out a tuberculosis diagnosis. Co-extraction of PCR inhibitors may be a cause of decreased test sensitivity. Here the design and early validation of a MTB screening assay with sample preparation and qPCR methods designed to specifically address this diagnostic gap is reported. First, human genomic DNA is identified as a significant qPCR inhibitor. To circumvent this problem, a novel, streamlined sample preparation method utilizing detergent and proteolysis to thin the sputum and DNA sequence specific MTB DNA isolation was developed. Additionally, a multiplexed qPCR assay targeting two MTB complex-specific loci: the potentially multi-copy IS6110 and the single-copy senX3-regX3, combined with the cotJC gene from Bacillus atrophaeus spores amplified as a process control was developed. The limit of detection of the test was estimated to be 20 cfu/ml which is significantly lower than the Xpert MTB/RIF assay. In a preliminary field study of 60 de-identified blinded sputa, a test sensitivity of 96% and specificity of 100% was observed when compared to the Xpert MTB/RIF assay.
Nucleic acid amplification tests are increasingly used to diagnose tuberculosis (TB) due to their speed and sensitivity compared to sputum smear microscopy. However, these tests fail to equal culture’s sensitivity with sputum smear microscopy negative specimens and therefore cannot be used to rule out TB disease. For molecular tests to match culture’s sensitivity, they must detect ≤10 genomic copies of Mycobacterium tuberculosis (MTB) DNA, the limit of detection of culture, process ≥1 ml of sputum ensuring sufficient number of MTB are in the reaction, and efficiently remove sputum associated inhibitors from this large sample. Here we report the preliminary characterization of XtracTB Assay, a MTB testing protocol designed for inclusion in either an integrated point-of-care platform or a high throughput automated central laboratory system. The test combines DNA sequence specific sample prep to reduce the co-extraction of qPCR inhibitors with the amplification of two MTB specific loci (IS6110 and senX3-regX3) to increase test sensitivity and minimize the likelihood of false negatives. The analytical sensitivity of the XtracTB Assay was 5 genomic copies/ml of sputum rivaling that of culture. Furthermore, 142 valid test results yield clinical sensitivity of 94.9% (95% CI: 90.1–99.9) and specificity of 100% (95% CI: 90.0–100.0).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.