PEREGRINE is a three-dimensional Monte Carlo dose calculation system written specifically for radiotherapy. This paper describes the implementation and overall dosimetric accuracy of PEREGRINE physics algorithms, beam model, and beam commissioning procedure. Particle-interaction data, tracking geometries, scoring, variance reduction, and statistical analysis are described. The BEAM code system is used to model the treatment-independent accelerator head, resulting in the identification of primary and scattered photon sources and an electron contaminant source. The magnitude of the electron source is increased to improve agreement with measurements in the buildup region in the largest fields. Published measurements provide an estimate of backscatter on monitor chamber response. Commissioning consists of selecting the electron beam energy, determining the scale factor that defines dose per monitor unit, and describing treatment-dependent beam modifiers. We compare calculations with measurements in a water phantom for open fields, wedges, blocks, and a multileaf collimator for 6 and 18 MV Varian Clinac 2100C photon beams. All calculations are reported as dose per monitor unit. Aside from backscatter estimates, no additional, field-specific normalization is included in comparisons with measurements. Maximum discrepancies were less than either 2% of the maximum dose or 1.2 mm in isodose position for all field sizes and beam modifiers.
Self-awareness of memory function is relatively well preserved in PD, but is negatively affected by depressive symptoms. Patient-proxy discrepancies increase also with disease severity, degree of memory problems and cognitive control deficits. Caregivers seem to be unaware of the specificity of memory problems in PD and report only some of them, mainly those related to verbal recall.
Individuals suffering from Huntington's disease (HD) have been shown to present with poor self-awareness of a variety of symptoms. The aim of this study was to better assess the self-awareness of motor symptoms and activities of daily living (ADL) impairment in HD, in comparison to Parkinson's disease (PD) and cervical dystonia (CD). In particular, the anosognosia/anosodiaphoria of involuntary movements has been investigated. Self-awareness was tested in 23 patients with HD by comparing patient and caregiver ratings in reference to clinical control groups (25 PD with dyskinesias, PDdys; 21 PD without dyskinesias, PDndys; and 20 with CD). Patients were assessed neurologically by relevant rating scales. Self-awareness was tested using a scale based on 15 films demonstrating 3 types of motor symptoms (chorea/dyskinesias, parkinsonism, torticollis) as well as the Self-Assessment Parkinson's Disease Disability Scale. General cognitive status, verbal learning, cognitive control, and mood were also analyzed. Our results indicate that self-awareness of choreic movements was affected more severely in HD than in PDdys, despite comparable cognitive status. Patient-proxy agreement on ADL impairment was roughly similar in all clinical groups. The results are discussed in the context of orbitofrontal-limbic pathology as a potential trigger of anosognosia/anosodiaphoria in individuals with HD.
To compare stereotactic radiosurgery (SRS) plan quality metrics of manual forward planning (MFP) and Elekta Fast Inverse Planning TM (FIP)-based inversely optimized plans for patients treated with Gamma Knife®. Clinically treated, MFP SRS plans for 100 consecutive patients (115 lesions; 67 metastatic and 48 benign) were replanned with the FIP dose optimizer based on a convex linear programming formulation. Comparative plans were generated to match or exceed the following metrics in order of importance: Target Coverage (TC), Paddick Conformity Index (PCI), beam-on time (BOT), and Gradient Index (GI). Plan quality metrics and delivery parameters between MFP and FIP were compared for all lesions and stratified into subgroups for further analysis. Additionally, performance of FIP for multiple punctate ( < 4 mm) metastatic lesions on a subset of cases was investigated. A Wilcoxon signed-rank test for non-normal distributions was used to assess the statistical differences between the MFP and FIP treatment plans. Overall, 76% (87/115) of FIP plans showed a statistically significant improvement in plan quality compared to MFP plans. As compared to MFP, FIP plans demonstrated an increase in the median PCI by 1.1% ( p < 0.01), a decrease in GI by 3.7% ( p < 0.01), and an increase in median number of shots by 74% ( p < 0.01). TC and BOT were not statistically significantly different between MFP and FIP plans ( p > 0.05). FIP plans showed a statistically significant increase in use of 16 mm ( p < 0.01) and blocked shots ( p < 0.01), with a corresponding decrease in 4 mm shots ( p < 0.01). Use of multiple shots per coordinate was significantly higher in FIP plans ( p < 0.01). The FIP optimizer failed to generate a clinically acceptable plan in 4/115 (3.5%) lesions despite optimization parameter changes. The mean optimization time for FIP plans was 5.0 min (Range: 1.0 -10.0 min). In the setting of multiple punctate lesions, PCI for FIP was significantly improved ( p < 0.01) by changing the default low-dose/BOT penalty optimization setting from a default of 50/50 to 75-85/40. FIP offers a significant reduction in manual effort for SRS treatment planning while achieving comparable plan quality to an expert planner-substantially improving overall planning efficiency. FIP plans employ a non-intuitive increased use of blocked sectors and shot-in-shot technique to achieve high quality plans. Several FIP plans failed to achieve clinically acceptable treatments and warrant further investigation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.