This paper presents a rapid less than 2 min and low-cost method involving the use of alkali solution to capture the acidic gasses from a biogas, thereby providing an estimate of the percentage of non-acidic gasses. Such a method was mentioned in the literature but never fully described or optimized. After sampling an aliquot of gas from bioprocess, gas was injected in a sealed flask with a 3 M NaOH solution, and after equilibrium was obtained, the non-acidic gas volume was measured. The method was first calibrated with certified gasses with an accuracy observed between 98 and 105%. Regarding the validation step, certified standard gas mixtures and nine biogas-laboratory batch reactors were used, the overall accuracy reported was 103 + 3%. This rapid and low-cost method may either be used in laboratory conditions as a quick and low cost alternative to standard analysis equipment or in addition as a routine field control method used on full-scale plants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.