The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability 1,2,3 and uncertainty, 4,5,6,7 are already being used to test physical theories 8,9 and herald a revision of the International System of units (SI). 10,11 However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, 12 a major challenge remains. This is their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations. 13,14,15 Here we report the first field measurement campaign performed with a ubiquitously applicable 87 Sr optical lattice clock. 13 We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km apart, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a 171 Yb lattice clock 16 also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks.The application of clocks in geodesy fulfils long-standing proposals to interpret a measurement of the fractional relativistic redshift Δνrel/ν0 to determine the gravity potential difference ΔU = c 2 Δνrel/ν0 between clocks at two sites (c being the speed of light). 12 National geodetic height systems based on classical terrestrial and satellite-based measurements exhibit discrepancies at the decimetre level. 17 Optical clocks, combined with high performance frequency dissemination techniques 18,19 offer an attractive way to resolve these discrepancies, as they combine the advantage of high spectral resolution with small error accumulation over long distances. 18,20 However, to achieve competitive capability requires high clock performance: a fractional frequency accuracy of 1×10 17 corresponds to a resolution of about 10 cm in height. Furthermore, it is important to realize that the sideby-side frequency ratio has to be known to determine the remote frequency shift Δνrel. Taking the uncertainty budgets of optical clocks for granted, harbours the possibility of errors, because very few have been verified experimentally to the low 10 17 region or beyond. 5,7,18,21 A transportable optical clock not only increases the flexibility in measurement sites but mitigates the risk of undetected errors by enabling local calibrations to be performed.The test site chosen for our demonstration of chronometric levelling 12 with optical clocks was the Laboratoire Souterrain de Modane (LSM) in France, with the Italian metrology institute INRIM in Torino serving as the reference site. The height difference between the two sites is approximately 1000 m, corresponding to a fractional redshift of about 10 -13 . From a geodetic point of view, LSM is a challenging and interesting location in which to perform such measurements: firstly, it is located in the middl...
The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level. Comparisons between earthbound clocks at rest must account for the relativistic redshift of the clock frequencies, which is proportional to the corresponding gravity (gravitational plus centrifugal) potential difference. For contributions to international timescales, the relativistic redshift correction must be computed with respect to a conventional zero potential value in order to be consistent with the definition of Terrestrial Time. To benefit fully from the uncertainty of the optical clocks, the gravity potential must be determined with an accuracy of about 0.1 m 2 s −2 , equivalent to about 0.01 m in height. This contribution focuses on the static part of the gravity field, assuming that temporal variations are accounted for separately by appropriate reductions. Two geodetic approaches are investigated for the derivation of gravity potential values: geometric levelling and the Global Navigation Satellite Systems (GNSS)/geoid approach. Geometric levelling gives potential differences with millimetre uncertainty over shorter distances (several kilometres), but is susceptible to systematic errors at the decimetre level over large distances. The GNSS/geoid approach gives absolute gravity potential values, but with an uncertainty corresponding to about 2 cm in height. For large distances, the GNSS/geoid approach should therefore be better than geometric levelling. This is demonstrated by the results from practical investigations related to three clock sites in Germany and one in France. The estimated uncertainty for the relativistic redshift correction at each site is about 2 × 10 −18 .
The latest generation of optical atomic clocks is approaching the level of one part in 10 18 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m 2 s −2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 10 18 . The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m 2 s −2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m 2 s −2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m 2 s −2 , while the range of the potential between specific laboratories is 0.3 and 1.1 m 2 s −2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10 −17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10 −18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.