BackgroundTympanic thermometry has come as a suitable alternative to traditional thermometry because of its safety and ease of use. However, it is still yet to gain wide acceptance in African settings due to conflicting results on its accuracy, thus rectal thermometry remains the gold standard in the newborn. The aim of this study was to compare tympanic and rectal temperatures in term Nigerian neonates.MethodsRectal and tympanic temperatures were measured simultaneously in 300 consecutive term neonates between the ages of 37 and 42 weeks gestation using mercury-in-glass and the Infrared tympanic thermometers respectively. Paired t test, Pearson correlation coefficient and the Bland-Altman plot were used to compute data. Using rectal thermometry as gold standard, the sensitivity, specificity and predictive values of tympanic thermometry at various rectal temperature cut-offs were determined. Receiver Operating Curves (ROC) were constructed and the Areas Under the Curves (AUC) were compared.ResultsThe mean rectal temperature (37.34 ± 0.55°C) was significantly higher than the mean tympanic temperature (37.25 ± 0.56°C) (p < 0.001) with a mean difference of 0.09 °C ± 0.24 °C (95% CI: 0.06, 0.12). There was a strong positive correlation between the two measurements (r = 0.9; p < 0.001). Tympanic thermometry showed sensitivities ranging from 65% to 86% and specificities of 95% to 99% at rectal temperature cut-offs of 37.5°C to 38°C. The positive and negative predictive values of the tympanic temperatures at the various temperature cut-offs ranged from 82% to 93% and 80% to 98% respectively. Accuracy was noted to increase with higher temperatures as shown by the Receiver Operating Curves with the highest accuracy at the temperature cut-off of 38°C and AUC of 0.91.ConclusionsThe sensitivity of tympanic thermometry was relatively low in detecting rectal temperatures despite the good correlation and agreement between them. The specificities and predictive values of tympanic temperatures in detecting rectal temperatures were high and accuracy increased with higher temperatures. Though using the tympanic route for measuring temperature in the newborn is relatively safe and non-invasive, its low sensitivity limits its use. Further studies would be required to further assess the accuracy of tympanic temperature measurements in the newborn.
SummaryBackgroundPaediatric cardiac services in Nigeria have been perceived to be inadequate but no formal documentation of availability and distribution of facilities and services has been done. Objective: To evaluate and document the currently available paediatric cardiac services in Nigeria.MethodsIn this questionnaire-based, cross-sectional descriptive study, an audit was undertaken from January 2010 to December 2014, of the personnel and infrastructure, with their distributions according to geopolitical zones of Nigeria.ResultsForty-eight centres participated in the study, with 33 paediatric cardiologists and 31 cardiac surgeons. Echocardiography, electrocardiography and pulse oximetry were available in 45 (93.8%) centres while paediatric intensive care units were in 23 (47.9%). Open-heart surgery was performed in six (12.5%) centres. South-West zone had the majority of centres (20; 41.7%).ConclusionsAvailable paediatric cardiac services in Nigeria are grossly inadequate and poorly distributed. Efforts should be intensified to upgrade existing facilities, establish new and functional centres, and train personnel.
Background: Malnutrition poses a great burden to children in the tropics. However, this seems to be accentuated in children with congenital heart disease.Objectives: The present study is therefore aimed at determining the nutritional status of children with congenital heart disease and to compare them with those without congenital heart disease.Methods: This is a cross-sectional study, where congenital heart disease was diagnosed by means of echocardiograph. Anthro software was used to calculate Z scores for weight for age (WAZ), height for age (HAZ), and weight for height (WHZ). Body mass index (BMI) was calculated by the formula BMI = Weight (Kg)/height (M2).Results: The body mass index-for-age z-score (BAZ) and height/length-for-age z-score (HAZ) were calculated for both subjects and controls to determine their nutritional status. It was observed that 38.5% (112/291) of the subjects were wasted (BAZ < −2SD) compared to 6.25% (16/256) of the controls and the difference was statistically significant (χ2 = 81.2, p < 0.001). Stunting (height/length-for-age z-score < −2SD) was also observed in a greater proportion of subjects than controls as 37.8% (107/291) of subjects were stunted compared with 7.0% (18/256) of the controls (χ2 = 69.9, p < 0.001). The under-five subjects had more cases of malnutrition than the controls of same age group as illustrated in Table 6. Whereas 42.9% (96/224) of the under-five subjects were wasted, only 6.2% (12/192) of the controls were wasted. On the other hand, 4.2% (8/192) of the under-five controls were obese compared to 0.9% (2/224) of the subjects of similar age group.Conclusion: Children with congenital heart disease present with varying degrees of malnutrition that is worse compared with children without congenital heart disease. The impact of malnutrition is worse among children under the age of five. Wasting is more prevalent in children with cyanotic heart disease compared with those with acyanotic congenital heart disease. Overweight and obesity were notable features of malnutrition in children with congenital heart disease, but this is worse in children without congenital heart disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.