Background/purpose The residual monomer remaining in acrylic resin can cause an allergic reaction and is toxic to oral soft tissue. This study determined the effect of the duration of ultrasonic cleaning on the amount of residual methyl methacrylate monomer in one heat-polymerized acrylic resin, Meliodent, and three autopolymerized acrylic resins, Unifast Trad Ivory, Unifast Trad Pink, and Unifast III. Materials and methods Thirty-six disc-shaped specimens of each brand were prepared and randomly divided into six groups: control (no treatment), positive control, and ultrasonic treatment in 50°C water for 3 minutes, 5 minutes, 10 minutes, or 15 minutes. The residual monomer was extracted and analyzed using high performance liquid chromatography. Results There were no significant differences in the residual monomer amount in the Meliodent groups. The amounts of residual monomer in the autopolymerized acrylic resin positive control group and ultrasonic treatment groups were significantly lower than those of the control group for the Unifast Trad Ivory, Unifast Trad Pink, and Unifast III groups (P < 0.05). The amount of residual monomer was not significantly different between the ultrasonic treatment in 50°C water (3 minutes for Unifast Trad Pink and 5 minutes for Unifast Trad Ivory and Unifast III) groups and the positive control group (P > 0.05). Conclusion Ultrasonic treatment with 50°C water for 3–5 minutes for autopolymerized resin and 3 minutes for heat-polymerized acrylic resin reduced the amount of residual monomer similarly to previously recommended methods, using shorter treatment times.
Surface treatment with MF-MA significantly enhanced the SBS of denture base resin and UT and UG compared to that of the groups treated with BA.
Objective Polylactic acid (PLA) is one of the most widely used materials in three-dimensional (3D) printing technology due to its multiple advantages such as biocompatibility and biodegradable. However, there is still a lack of study on 3D printing PLA for use as a denture base material. The goal of this study was to compare 3D printing PLA to traditional poly(methyl methacrylate) (PMMA) as a denture basis. Materials and Methods The PMMA (M) and PLA (L) specimens were fabricated by compression molding, and fuse deposition modeling technique, respectively. Each specimen group was divided into three different temperature groups of 25°C (25), 37°C (37), and 55°C (55). The glass transition temperature (Tg) of raw materials and specimen was investigated using differential scanning calorimetry. The heat deflection temperature (HDT) of each material was also observed. Statistical Analysis The data of flexural strength and flexural modulus were analyzed with two-way analysis of variance, and Tukey honestly significant difference. The Tg and HDT data, on the other hand, were descriptively analyzed. Results The results showed that PLA had lower flexural strength than PMMA in all temperature conditions, while the PMMA 25°C (M25) and PMMA 37°C (M37) obtained the highest mean values. PLA 25°C (L25) and PLA 37°C (L37) had significant higher flexural modulus than the other groups. However, the flexural properties of L55 could not be observed, which may be explained by Tg and HDT of PLA. Conclusion PLA only meets the flexural modulus requirement, although it was greater than flexural modulus of PMMA. On the other hand, PMMA can meet both good flexural strength and modulus requirement. However, increase in temperature could reduce flexural strength and flexural modulus of PMMA and PLA.
PURPOSEThis study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin.MATERIALS AND METHODSSeventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05).RESULTSThe surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05).CONCLUSION15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.