BackgroundThe most common mechanical failure in the internal fixation of trochanteric hip fractures is the cut-out of the sliding screw through the femoral head. Several factors that influence this complication have been suggested, but there is no consensus as to the relative importance of each factor.The purpose of this study was to analyse the cut-out complication with respect to the following variables: patients’ age, fracture type, fracture reduction, implant positioning and implant design.Methods3066 consecutive patients were treated for trochanteric fractures with Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l`Orthopedie (CTO), Strasbourg, France. Cut-out complications were identified by reviewing all available case notes and radiographs. Subsequently, the data were analysed by a single reviewer (AJB) with focus on the studied factors.ResultsSeventy-one cut-out complications were found (2.3%) of the 3066 trochanteric fractures. Cut-out failure associated with avascular head necrosis, pathologic fracture, deep infection or secondary to prior failure of other implants were excluded from the study (14 cases). The remaining 57 cases (1.85 %, median age 82.6, 79% females) were believed to have a biomechanical explanation for the cut-out failure. 41 patients had a basicervical or complex fracture type. A majority of cut-outs (43 hips, 75%) had a combination of the critical factors studied; non-anatomical reduction, non-optimal lag screw position and the characteristic fracture pattern found.ConclusionsThe primary cut-out rate of 1.85% was low compared with the literature. A typical cut-out complication in our study is represented by an unstable fracture involving the trochanteric and cervical regions or the combination of both, non-anatomical reduction and non-optimal screw position. Surgeons confronted with proximal femoral fractures should carefully scrutinize preoperative radiographs to assess the primary fracture geometry and fracture classification. To reduce the risk of a cut-out it is important to achieve both anatomical reduction and optimal lag screw position as these are the only two factors that can be controlled by the surgeon.
BackgroundHumeral fractures are common, but the association between the patho-anatomical fracture pattern and patient characteristics has been inadequately studied and epidemiological knowledge is scarce. Following the introduction of the Swedish Fracture Register (SFR), risk factors for various fractures can be studied, as well as the outcome of different treatments. The objective of this study was to analyse adult humeral fractures in Gothenburg from a descriptive epidemiological perspective.MethodsAll humeral fractures registered in the SFR at Sahlgrenska University Hospital in 2011–2013 in patients aged ≥ 16 years were included. The fractures were divided into humeral segments (proximal, shaft and distal humerus) and analysed according to patient characteristics and patho-anatomical pattern. Furthermore, overall and age-specific incidence rates were calculated.ResultsA total of 2,011 humeral fractures were registered in the SFR, of which 79 % were proximal, 13 % shaft and 8 % distal humeral fractures. The mean age was 66.8 years and women ran a higher risk of humeral fractures than men (female/male ratio 2.4:1). On average, women were older than men at the time of fracture (mean age 70.1 years for women vs. 58.9 years for men). The overall incidence of humeral fractures was 104.7 per 100,000 inhabitants per year, with a segment-specific incidence of 83.0 for proximal fractures, 13.4 for shaft fractures and 8.3 per 100,000 person-years for distal fractures. There was a distinct increase in the age-specific incidence from the fifth decade and onwards, regardless of fracture site. Most fractures occurred in older patients (83 % > 50 years) as a result of a simple or an unspecified fall (79 % > 50 years). Only 1.2 % of all fractures were open injuries and 1.3 % were pathological.ConclusionThis population-based study provides updated epidemiological data on humeral fractures in a Western-European setting. Most humeral fractures occur as the result of low-energy falls in the elderly population, indicating the influence of age-related risk factors in these fractures. The SFR will be a useful tool for providing continuous information on fracture epidemiology, risk factors and treatment outcome and these population-based data are essential in the planning of future fracture prevention and management.
BackgroundFixation of trochanteric hip fractures using the Gamma Nail has been performed since 1988 and is today well established and wide-spread. However, a number of reports have raised serious concerns about the implant's complication rate. The main focus has been the increased risk of a subsequent femoral shaft fracture and some authors have argued against its use despite other obvious advantages, when this implant is employed.Through access to a uniquely large patient data base available, which is available for analysis of trochanteric fractures; we have been able to evaluate the performance of the Gamma Nail over a twelve year period.Methods3066 consecutive patients were treated for trochanteric fractures using Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l'Orthopedie (CTO), Strasbourg, France. These patients were retrospectively analysed. Information on epidemiological data, intra- and postoperative complications and patients' outcome was retrieved from patient notes. All available radiographs were assessed by a single reviewer (AJB).ResultsThe results showed a low complication rate with the use of the Gamma Nail. There were 137 (4.5%) intraoperative fracture-related complications. Moreover 189 (6.2%) complications were detected postoperatively and during follow-up. Cut-out of the lag screw from the femoral head was the most frequent mechanical complication (57 patients, 1.85%), whereas a postoperative femoral shaft fracture occurred in 19 patients (0.6%). Other complications, such as infection, delayed healing/non-union, avascular femoral head necrosis and distal locking problems occurred in 113 patients (3.7%).ConclusionsThe use of the Gamma Nail in trochanteric hip fractures is a safe method with a low complication rate. In particular, a low rate of femoral shaft fractures was reported. The low complication rate reported in this series can probably be explained by strict adherence to a proper surgical technique.
We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients. Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty.
BackgroundAlthough fractures consume large social and financial resources, little is known about their actual numbers, treatment methods or outcomes. The scarcity of data calls for a high-quality, population-based register. No previous registers have prospectively collected data and patient-reported outcome measures (PROMs) on fractures of all types. The Swedish Fracture Register was recently created to fill this gap in knowledge. Its purpose is to provide information on fractures of all types, whether treated by surgery or otherwise. The aim of this article is to describe how the register was developed and its current use.DescriptionThe Swedish Fracture Register was developed during a 4-year period, 2007–2010. Data collection started in 2011. The register currently collects data on all extremity, pelvic and spine fractures in adults who have been diagnosed or treated at the affiliated departments. Data entry is fully web based, including date, cause of injury, classification and treatment. It is performed by the attending physician. Patients fill out PROMs – EQ-5D-3L and the Short Musculoskeletal Function Assessment (SMFA) – relating to health status and level of functioning before the fracture and one year later. Surgeon-reported outcome measures are registered as reoperation rates. The Swedish Fracture Register is now functioning effectively and is used in clinical routine. From January 2011 to September 2015, more than 103,000 fractures have been entered at 26 Swedish orthopedic departments.ConclusionsThe Swedish Fracture Register is already a well-functioning, population-based fracture register that covers fractures of all types, regardless of treatment, and collects both surgeon- and patient-reported outcome measures. In the future the Swedish Fracture Register will be able to present both results of fracture treatment and valuable epidemiological data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.