This study attempted to identify and characterize bacteria present on shared-use protective lead shielding garments worn in the operating room. Those worn at the authors' institution were collected and swabbed in designated 5×5-cm areas. Swabs were sent to the clinical laboratory for bacterial isolation and identification. All isolates were identified using standard microbiological methods. Isolates then underwent antimicrobial susceptibility testing as per standard hospital procedures. Of 182 total collected swabs, bacteria were isolated on only 5 (2.7%) samples. Coagulase-negative Staphylococci was identified on 3 samples and the remaining 2 grew coagulase-negative Staphylococci and gram-positive rods. The collection sites for these isolates were the lead apron, midline, bottom outer surface (n=3), thyroid shield midline, inner surface (n=1), and skirt midline, bottom inner surface (n=1). Of the collected samples, 98.3% were negative for bacterial growth. The remaining isolates were consistent with common skin flora. No multi-drug resistant organisms were identified on any garments. Standard cleaning procedures at the institution are an effective way to prevent growth of bacteria on shared-use protective lead shielding garments worn in the operating room.
Introduction: The rate of preoperative osteoporosis in lower extremity arthroplasty is 33%. The prevalence of osteoporosis in shoulder arthroplasty patients is inadequately studied. The purpose of this study was to (1) determine the prevalence of osteoporosis in patients undergoing elective shoulder arthroplasty, (2) report the percentage of patients having dual-energy x-ray absorptiometry (DEXA) testing before surgery, and (3) determine the percentage of patients who have been prescribed osteoporosis medications within 6 months before or after surgery. Methods: This retrospective case series included all adults aged 50 years and older who underwent elective shoulder arthroplasty at a single tertiary care center over an 8-year period. National Osteoporosis Foundation (NOF) criteria for screening and treatment were applied. Results: Two hundred fifty-one patients met the inclusion criteria; 171 (68%) met the criteria for DEXA testing, but only 31 (12%) had this testing within 2 years preoperatively. Eighty patients (32%) met the NOF criteria for receipt of pharmacologic osteoporosis treatment, and 17/80 (21%) received a prescription for pharmacotherapy. Discussion: Two-thirds of elective shoulder arthroplasty patients meet the criteria to have bone mineral density measurement done, but less than 20% have this done. One in three elective shoulder arthroplasty patients meet the criteria to receive osteoporosis medications, but only 20% of these patients receive therapy.
Meniscal injuries are an extremely common cause of knee pain. Meniscal repairs performed with concomitant anterior cruciate ligament reconstruction appear to heal at a higher rate than meniscal repairs performed in isolation. This may be due in part to the release of marrow elements into the knee and the time of meniscal repair. In cases of isolated meniscal repair, some orthopedic surgeons use microfracture to release marrow elements into the joint as an adjunct to enhance meniscal healing. This study evaluated rates of meniscal tear healing with or without the performance of microfracture in a goat (Capra hircus) model. Forty castrated young adult male goats underwent either a horizontal or a longitudinal 1.0-cm meniscal tear with or without microfracture. All procedures were performed open, in a bloodless field. Meniscal tears were created in the peripheral half of the body of the medial meniscus. The goats were euthanized at 6 months, and meniscal tears were analyzed and classified as complete healing, partial healing, or no healing by direct visualization. A probe was used as an aid to evaluate and classify the meniscal tears. Twenty (87%) of 23 goat meniscal tears showed at least partial healing when performed with concomitant microfracture. Only 5 (29%) of 17 menisci showed any healing in goats that did not receive microfracture. This difference in healing rates was statistically significant (P<.001). Fifteen (65%) meniscal tears accomplished with microfracture were completely healed, whereas only 2 (12%) menisci showed complete healing without microfracture (P<.001). The results of this study suggest that the release of bone marrow elements into the knee by microfracture improves meniscal healing rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.