Platelet glycoprotein (GP) VI is a 62-kDa membrane glycoprotein that exists on both human and murine platelets in a noncovalent complex with the Fc receptor (FcR) ␥ chain. The GPVI/FcR␥-chain complex serves as the major activating receptor for collagen, as evidenced by observations that platelets genetically deficient in GPVI or the FcR␥ chain are highly refractory to collagen-induced platelet activation. Recently, several different rat anti-murine GPVI monoclonal antibodies, termed JAQs 1, 2, and 3, were produced that had the unique property of "immunodepleting" GPVI from the murine platelet surface and rendering it unresponsive to collagen or GPVI-specific agonists like convulxin or collagen-related peptide (CRP). Herein, we describe a patient with a mild bleeding disorder and a moderately reduced platelet count whose platelets fail to become activated in response to collagen or CRP and inefficiently adhere to and form thrombi on immobilized collagen under conditions of arterial shear. Although the amount of GPVI platelet mRNA and the nucleotide sequence of the GPVI gene were found to be normal, both GPVI and the FcR␥ chain were nearly absent from the platelet surface and were markedly reduced in wholeplatelet detergent lysates. Patient plasma contained an autoantibody that bound specifically to GPVI-positive, normal platelets, and cleared soluble GPVI from the plasma, suggesting that the patient suffers from a rare form of idiopathic thrombocytopenic purpura caused by a GPVIspecific autoantibody that mediates clearance of the GPVI/FcR␥-chain complex from the platelet surface. Since antibody-induced GPVI shedding now has been demonstrated in both humans and mice, these studies may provide a rationale for developing therapeutic reagents that induce temporary depletion of GPVI for the treatment of clinical thrombosis.
Summary
Background
Detection and validation of inhibitors (antibodies) to hemophilia treatment products are important for clinical care, evaluation of product safety, and assessment of population trends.
Methods
Centralized monitoring for factor VIII (FVIII) inhibitors was conducted for patients in the Hemophilia Inhibitor Research Study using a previously reported modified Nijmegen-Bethesda clotting assay (NBA), a chromogenic Bethesda assay (CBA), and a novel fluorescence immunoassay (FLI).
Results
NBA and CBA were performed on 1005 specimens and FLI on 272 specimens. CBA was negative on 880/883 specimens (99.7%) with Nijmegen-Bethesda units (NBU)<0.5 and positive on 42/42 specimens (100%) with NBU≥2.0 and 43/80 specimens (53.8%) with NBU 0.5–1.9. Among specimens with positive NBA and negative CBA, 58.1% were FLI-negative, 12.9% had evidence of lupus anticoagulant, and 35.5% had non-time-dependent inhibition. CBA and FLI were positive on 72.4% and 100% of 1.0–1.9 NBU specimens and 43.1% and 50.0% of 0.5–0.9 NBU specimens. FLI detected antibodies in 98.0% of CBA-positive and 81.6% of NBA-positive specimens (P=0.004). Among 21 new inhibitors detected by NBA, 5 (23.8%) with 0.7–1.3 NBU did not react in CBA or FLI. Among previously positive patients with 0.5–1.9 NBU, 7/25 (28%) were not CBA or FLI positive. FLI was positive on 36/169 NBU-negative specimens (21.3%).
Conclusions
FVIII specificity could not be demonstrated by CBA or FLI for 26% of inhibitors of 0.5–1.9 NBU; such results must be interpreted with caution. Low titer inhibitors detected in clot-based assays should always be repeated, with consideration given to evaluating their reactivity with FVIII using more specific assays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.