Successful pAVFs with proximal radial artery inflow were created with excellent initial results regarding technical success, patency, and safety. Advantages include avoidance of a surgical incision, short procedure times, good acceptance by patients, prompt access maturation, moderate flow, and low-pressure access, with possible reduction of risk for ischemic complications. Avoidance of vessel manipulation and side branch ligation might reduce risk of thrombosis and improve long-term patency and reduce need for further interventions. These early findings need to be confirmed in larger and longer follow-up studies.
Objective: The aim of this study was to report our midterm results of percutaneous arteriovenous fistula (pAVF) creation using the Ellipsys (Avenu Medical, San Juan Capistrano, Calif) device and to present technical recommendations and our algorithm of pAVF maintenance.Methods: A single-center comprehensive database of all consecutive predialysis and end-stage renal disease patients who had a pAVF creation with the Ellipsys device was reviewed retrospectively. Study end points included technical success, maturation, functional patency, and required interventions.Results: Between May 2017 and July 2019, there were 234 patients (mean age, 64 years; 148 male [63%]) who had a pAVF created. Technical success was achieved in 232 individuals (99%), and average duration of the procedure was 15 minutes (7-35 minutes). Average follow-up was 252 days (range, 83-696 days). The 1-year primary, primary assisted, and secondary patency rates were 54%, 85%, and 96%, respectively. Average pAVF flow was 923 mL/min (range, 425-1440 mL/min). There were no significant adverse events related to the procedure. Only three patients (1%) required a later conversion of the pAVF anastomosis to a surgical fistula. Twenty-four (10%) patients required superficialization of deep outflow veins because of difficult cannulation. Average maturation time was 4 weeks (range, 1-12 weeks). Fourteen patients (6%) had early (<2 weeks after creation) cannulation of the pAVF.
Conclusions:The Ellipsys pAVF device allows the rapid and safe creation of a reliable autogenous access. Rates of technical success, patency, and maturation were excellent. For patients unsuited for a distal radiocephalic arteriovenous fistula, it should be considered the next preferred access option.
The endovascular management of TRAS is safe and presents a high rate of technical success with low morbidity. Its impact on serum creatinine levels is significant in our experience. However, the blood pressure items do not seem to improve postoperatively.
Endovascular stent grafting allows an immediate efficient repair for acute traumatic injuries of the thoracic aorta. This early management is, however, associated with a high in-hospital mortality, related to the severe concomitant injuries of such unselected multitrauma patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.