A highly selective, sensitive and accurate HPLC method has been developed and validated for the estimation of four proton-pump inhibitors (PPI), lansoprazole (LPZ), omeprazole (OPZ), pantoprazole (PPZ) and rabeprazole (RPZ), with 500 microL human plasma using zonisamide as an internal standard (IS). The sample preparation involved simple liquid-liquid extraction of LPZ, OPZ, PPZ and RPZ and IS from human plasma with ethyl acetate. The baseline separation of all the peaks was achieved with 0.1% triethylamine (pH 6.0):acetonitrile (72:28, v/v) at a flow rate of 1 mL/min on a Zorbax C(8) column. The total chromatographic run time was 11.0 min and the simultaneous elution of IS, OPZ, RPZ, PPZ and LPZ occurred at approximately 2.42, 4.45, 5.02 and 9.37 min, respectively. The method was proved to be accurate and precise at linearity range of 20.61-1999.79 ng/mL with a correlation coefficient (r) of >or=0.999. The limit of quantitation for each of the PPI studied was 20.61 ng/mL. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers.
A highly sensitive, rapid assay method has been developed and validated for the estimation of montelukast (MTK) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electro spray ionization in the positive-ion mode. Liquid-liquid extraction was used to extract MTK and amlodipine (internal standard, IS) from human plasma. Chromatographic separation was achieved with 10 mM ammonium acetate (pH 6.4): acetonitrile (15:85, v/v) at a flow rate of 0.50 mL/min on a Discovery HS C(18) column with a total run time of 3.5 min. The MS/MS ion transitions monitored were 586.10 --> 422.10 for MTK and 409.20 --> 238.30 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.25 ng/mL and linearity was observed from 0.25 to 800 ng/mL. The intra-day and inter-day precisions were 5.97-8.33 and 7.09-10.13%, respectively. This novel method has been applied to a pharmacokinetic study of MTK in humans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.