In a preclinical model, HP-SD ablation (90 W/4 s, T ≤65°C) produced an improved lesion-to-lesion uniformity, linear contiguity, and transmurality at a similar safety profile of conventional ablation.
Background
- With short radiofrequency (RF) applications, tissue temperature continues to rise after RF-termination ("thermal latency"), which may result in lesion growth after RF-termination. The purpose was to compare
in-vivo
tissue temperature profile (thermal latency), lesion size and the incidence of steam pop and thrombus between RF-ablation with very-high-power-very-short-RF(90W/4s), high-power-short-RF(50W/10s) and moderate-power-moderate-RF(30W/30s) in a canine thigh muscle preparation and beating heart.
Methods
- In the thigh muscle preparation (5dogs), a 3.5mm ablation-electrode with 66 or 56 small irrigation holes (QDOT-Micro or ThermoCoolSmartTouch-SF, respectively) was held perpendicular or parallel to the muscle at 10 or 30g contact force (CF). Total of 120RFs were delivered at 90W/4s(QDOT-catheter), 50W/10s or 30W/30s(SF-catheter). Electrode temperature, electrode-tissue-interface temperature and tissue temperatures at 3mm and 7mm-depths were measured. In 6 closed-chest dogs, total of 72RFs were delivered in the ventricle at 90W/4s, 50W/10s or 30W/30s.
Results
- In the thigh muscle preparation, tissue temperatures and lesion size (depth, diameter and volume) were lowest/smallest for RFs at 90W/4s, followed by 50W/10s and greatest for 30W/30s. Thermal latency (Δtemperature and duration) was greatest for RFs at 90W/4s, followed by 50W/10s and smallest for 30W/30s (
p
<0.01). Effective tissue heating (area under curve≥50°C at 3mm-depth) was observed after RF-termination in 88.0±7.6% with 90W/4s, 57.7±14.6% with 50W/10s, and only 31.9±8.5% with 30W/30s (
p
<0.01). In beating hearts, lesion size was also smallest with 90W/4s and greatest with 30W/30s RFs. Increasing CF significantly increased lesion depth in all three groups. There was no significant difference in the incidence of steam pop or thrombus between three groups.
Conclusions
- Tissue temperatures and lesion size (depth, diameter and volume) were lowest/smallest for RF-applications at 90W/4s, followed by 50W/10s and greatest for 30W/30s. The greater thermal latency for 90W/4s RF-applications suggests that a significant portion of lesion is created after RF-termination due to conductive tissue heating.
Delivery of high-power short-duration RF energy applications, facilitated by a novel ablation catheter system equipped with advanced TC technology, is feasible, safe, and results in the formation of effective ablation lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.