London, United Kingdom BACKGROUND: Smartphone applications (apps) have become integrated with many aspects of modern life, with >100,000 apps currently available for use in healthcare. Apps are unregulated and potentially place patients at risk if the information they contain is inaccurate. Additionally, any app that transforms clinical data (e.g. calculating a mean blood pressure (BP)) is a Class 1 medical device and should be registered with the Medicines and Healthcare Regulatory Agency in the UK. Here we present a systematic review of blood pressure (BP) monitoring apps available in the UK. METHODS: The Apple App Store (UK) was searched on 15th March 2014 using the terms "hypertension" OR "blood pressure". Inclusion criteria were iPhone compatibility, free to use, English language, targeted for patient use, ability to record multiple BP readings and app functionality independent of other medical devices. Data were extracted from each app according to a predefined protocol: conformity to guidelines, presence of data transformation, limits to data input and data protection policy. RESULTS: Following the removal of duplicates, 608 apps were identified of which 96 met the inclusion criteria. Five apps provided advice on how to measure BP, of which four claimed conformity to national and/or international guidelines. A further 11 apps providing advice unrelated to BP measurement technique also claimed conformity to guidelines (15 apps in total; 16%). No apps stated approval by recognised societies.Data transformation was performed by 24 apps (25%), none of which displayed regulatory approval. Three apps did recommend using a specific approved sphygmomanometer, with one providing formulae used for subsequent data transformation.Data input was subject to checks in 60% (58 apps) to ensure that diastolic values were lower than systolic. 25% (24 apps) required a passcode to access stored data, but it was unclear where data was stored (e.g. locally on device or on a server) in 89% of apps. CONCLUSION: There are many apps freely available to patients that enable them to record BP measurements. These unregulated apps conform poorly to recognised guidelines and have the potential to harm if their advice or data transformations are inaccurate.
ResumoA pressão arterial vem recebendo destaque na clínica veterinária atual, podendo ser mensurada de forma não-invasiva, pelo método oscilométrico, entre outros. Fatores como a idade já foram relacionados com distúrbios na pressão arterial. O sódio, elemento vital na fisiologia celular de animais, já foi relacionado com o aumento da pressão arterial. Desta forma, este trabalho correlaciona a idade, os valores da pressão arterial sistêmica, sistólica e diastólica, com os níveis séricos de sódio em cães adultos hígidos. Foram estudados 23 cães adultos, hígidos, de ambos os sexos e idade variável, alimentados com ração comercial (standard). As pressões arteriais, sistólica (PAS) e diastólica (PAD), e pulso foram aferidas por esfigmomanômetro digital humano. O nível sérico de sódio foi obtido pelo método de reagente enzimático em modo cinético, utilizando kit comercial. Foi realizada a Correlação de Pearson entre as variáveis. Os valores da PAS, PAD, pulso e sódio sérico, variaram respectivamente de 96 -184mmHg, 53-137mmHg, 64 -135bpm e 120 -157mEq/L. Foi observada uma correlação positiva entre as variáveis idade e PAS, idade e PAD, sódio e PAS, e sódio e PAD, enquanto os valores de idade e sódio sérico, demonstraram uma correlação negativa. Nas condições deste estudo conclui-se que há pouca interferência nos valores de pressão arterial, sistólica e diastólica, pela idade e o nível sérico de sódio, em cães adultos hígidos. Palavras-chave: Pressão diastólica, pressão sistólica, pulso, oscilométrico, dosagem de sódio AbstractBlood pressure has received attention in current veterinary clinic and can be measured in a non-invasive way by the oscillometric method, among others. Factors such as age have already been related to disorders on blood pressure. Sodium, vital element in cell physiology of animals, has been reported to increase blood pressure. Thus, this work correlates age, the values of blood pressure, both systolic and diastolic, with the serum levels of sodium in healthy adult dogs. We studied 23 adult healthy dogs of both sexes and varying age fed with commercial feed (standard). The arterial pressure, systolic (SBP) and diastolic (DBP), and pulse were measured by digital human sphygmomanometer. The level of serum sodium was obtained by the method of enzyme reagent in kinetic mode, using a commercial kit. We performed Pearson correlation between variables. The values of SBP, DBP, pulse and serum sodium varied respectively from 96 -184mmHg, 53 -137mmHg, 64 -135bpm and 120-157mEq/L. We
ResumoA pressão arterial vem recebendo destaque na clínica veterinária atual, podendo ser mensurada de forma não-invasiva, pelo método oscilométrico, entre outros. Fatores como a idade já foram relacionados com distúrbios na pressão arterial. O sódio, elemento vital na fisiologia celular de animais, já foi relacionado com o aumento da pressão arterial. Desta forma, este trabalho correlaciona a idade, os valores da pressão arterial sistêmica, sistólica e diastólica, com os níveis séricos de sódio em cães adultos hígidos. Foram estudados 23 cães adultos, hígidos, de ambos os sexos e idade variável, alimentados com ração comercial (standard). As pressões arteriais, sistólica (PAS) e diastólica (PAD), e pulso foram aferidas por esfigmomanômetro digital humano. O nível sérico de sódio foi obtido pelo método de reagente enzimático em modo cinético, utilizando kit comercial. Foi realizada a Correlação de Pearson entre as variáveis. Os valores da PAS, PAD, pulso e sódio sérico, variaram respectivamente de 96 -184mmHg, 53-137mmHg, 64 -135bpm e 120 -157mEq/L. Foi observada uma correlação positiva entre as variáveis idade e PAS, idade e PAD, sódio e PAS, e sódio e PAD, enquanto os valores de idade e sódio sérico, demonstraram uma correlação negativa. Nas condições deste estudo conclui-se que há pouca interferência nos valores de pressão arterial, sistólica e diastólica, pela idade e o nível sérico de sódio, em cães adultos hígidos. Palavras-chave: Pressão diastólica, pressão sistólica, pulso, oscilométrico, dosagem de sódio AbstractBlood pressure has received attention in current veterinary clinic and can be measured in a non-invasive way by the oscillometric method, among others. Factors such as age have already been related to disorders on blood pressure. Sodium, vital element in cell physiology of animals, has been reported to increase blood pressure. Thus, this work correlates age, the values of blood pressure, both systolic and diastolic, with the serum levels of sodium in healthy adult dogs. We studied 23 adult healthy dogs of both sexes and varying age fed with commercial feed (standard). The arterial pressure, systolic (SBP) and diastolic (DBP), and pulse were measured by digital human sphygmomanometer. The level of serum sodium was obtained by the method of enzyme reagent in kinetic mode, using a commercial kit. We performed Pearson correlation between variables. The values of SBP, DBP, pulse and serum sodium varied respectively from 96 -184mmHg, 53 -137mmHg, 64 -135bpm and 120-157mEq/L. We
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.