Recent decades have seen BCI applications as a novel and promising new channel of communication, control and entertainment for disabled and healthy people. However, BCI technology can be prone to errors due to the basic emotional state of the user: the performance of reactive and active BCIs decrease when user becomes stressed or bored, for example. Passive-BCI is a recent approach that fuses BCI technology with cognitive monitoring, providing valuable information about the user's intentions, the situational interpretations and mainly the emotional state. In this work, an architecture composed by passive-BCI co-working with SSVEP-BCI is proposed, with the aim of improving the performance of the reactive-BCI. The possibility of adjusting recognition characteristics of SSVEP-BCIs using a passive-BCI output is evaluated. In this sense, two ways to recover the accuracy of SSVEP are presented in this paper: 1) Adjusting of Amplitude of the SSVEP and 2) Adjusting of Frequency of the SSVEP response. The results are promising, because accuracy of SSVEP-BCI can be recovered in the case that it was reduced by the BCI user's emotional state.
In optical systems, the range of distance near the point of focus where objects are perceived sharply is referred as depth-of-field; objects outside this region are defocused and blurred. Furthermore, ophthalmology studies state that the amplitude and the latency of visual evoked potentials are affected by defocusing. In this context, this paper evaluates a novel setup for a steady-state visual evoked potential (SSVEP) brain-computer interface, in which two stimuli are presented together in the center of the user's field of view but at different distances ensuring that if one stimulus is focused on, the other one is non-focused, and vice versa. The evaluationwas conductedwith eight healthy subjects who were asked to focus on just one stimulus at a time. An average accuracy rate of 0.93 was achieved for a time window of 4 s by employing well know SSVEP detection methods. Results show that distinguishable SSVEP can be elicited by the focused stimulus regardless of the non-focused one is also present in the field of view. Finally, this approach allows users to send commands through a stimuli selection by focusing mechanism that does not demand neck, head, and/or eyeball movements.
Introduction:The main drawback of a Brain-computer Interface based on Steady-State Visual Evoked Potential (SSVEP-BCI) that detects the emergence of visual evoked potentials (VEP) in reaction to flickering stimuli is its muscular dependence due to users must redirect their gaze to put the target stimulus in their field of view.In this work, a novel setup is evaluated in which two stimuli are placed together in the center of users' field of view, but with dissimilar distances from them, so that the target selection is performed by focus shifting instead of head, neck and/or eyeball movements. Methods: A model of VEP generation for the novel setup was developed. The Spectral F-test based on Bartett periodogram was used to evaluate the null hypothesis of absence of effects of the non-focused stimulus (NFS) within the VEP elicited by the focused stimulus (FS).To reinforce that there is not statistical evidence to support the presence of NFS effects, the PSDA detection method was employed to find the frequency of FS. Electroencephalographic signals of nine subjects were recorded. Results: Approximately in 80% of the tests, the null hypothesis with 5% level of significance was non-rejected at the fundamental frequency of NFS. The average of the accuracy rate attained with PSDA detection method was 79.4%. Conclusion: Results of this work become further evident to state that if the focused stimulus (FS) will be able to elicit distinguishable VEP pattern regardless the non-focused stimulus (NFS) is also present.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.