Orthopantomographs taken from 308 Spanish Caucasian and 200 Venezuelan Amerindian children, aged between 2 and 18 years, were analysed following the Demirjian's method. The aims of this study were to test the applicability of the Demirjian's method to two different sample populations, and to develop age prediction models for both populations using the original French Canadian scores described by Demirjian (1976) and the new multi-ethnic dental scores proposed by Chaillet et al. (2005) when the ethnic origin is unknown. Results showed that despite the good correlation between dental and chronological age, Demirjian's method overestimates the age in the Spanish Caucasian sample using both scores, the mean overestimation being higher when the Demirjian's scores were used than when the Chaillet's scale was applied. In the Venezuelan Amerindian sample, the opposite was found: Demirjian's method underestimates the age using both scores, the underestimation being higher when the Chaillet's scale was applied than when Demirjian's scale was used. New graphs were produced to convert the maturity scores to dental age for Spanish and Venezuelan children. With these graphs, the Demirjian's scores showed to be inadequate after the age of 12 in both populations, while Chaillet's scores offered useful information until 14 years of age.
Drug exposure during pregnancy constitutes a major legal issue and a public health concern. Drug and metabolite determination in biological matrices from mother and newborn is an objective indication of prenatal drug exposure. However, limited data are available regarding the interpretation of these analytical results in terms of window of detection and degree of exposure. We collected paired maternal hair, meconium, placenta, and umbilical cord from 727 mother-newborn dyads. We analyzed these specimens by liquid chromatography-tandem mass spectrometry for the determination of cocaine, opioids, methadone, and amphetamines, and compared the analytical results from the four different matrices. The cases were divided in non-exposure, low, and frequent exposure, based on maternal hair concentrations and segmental analysis by trimesters. For cocaine, 62 cases tested positive in hair, 9 in meconium, 6 in placenta and 7 in umbilical cord. In the case of opioids, 14 maternal hair cases were positive, 11 meconium and umbilical cord and 9 placenta samples. For methadone, 11 cases were positive in hair, 9 in meconium and 6 in placenta and umbilical cord. For amphetamines, 18 cases were positive according to maternal hair, but all meconium, placenta, and umbilical cord tested negative. Maternal hair was the most sensitive specimen to detect drug exposure during pregnancy. Meconium, placenta, and umbilical cord tested positive if hair concentrations showed frequent drug use during the whole pregnancy, especially during the third trimester. Meconium, placenta, and umbilical cord also tested positive for morphine and metabolites, if this drug was administered during labour and delivery. Copyright © 2016 John Wiley & Sons, Ltd.
Maternal hair is the most sensitive specimen to detect drug consumption during pregnancy. Placenta and umbilical cord could be alternatives to meconium for detecting high in utero drug exposure.
According to the 2014 National Survey on Drug Use and Health, 5.3% of pregnant women smoked marijuana in the past month. This prevalence is expected to increase as a growing number of states and countries are now considering legalization. Although the umbilical cord is becoming a useful objective tool to detect in utero drug exposure, currently data about analytical methods and its utility to detect cannabis exposure are scarce. The objective of this work was to develop a method for the determination of Δ -tetrahydrocannabinol (THC), 11-hydroxyTHC (THC-OH), 11-nor-9-carboxy-THC (THCCOOH), 8-β-11-dihydroxyTHC (THC-diOH), THC and THCCOOH glucuronides, and cannabidiol (CBD) in the umbilical cord by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with dual ionization source. Umbilical cord samples (0.5 g) were homogenized in methanol and extracted by solid-phase extraction. Reversed-phase chromatographic separation was performed in 14 minutes, and 2 transitions per analyte were monitored in multiple reaction monitoring mode. Method validation included linearity (1-10 to 20-200 ng/g), precision (4.1%-23.4%), accuracy (87.5%-111.4%), matrix effect (-54.8% to -5.8%), extraction efficiency (25%-45.6%), limits of detection and quantification (1-10 ng/g), and endogenous (n = 5) or exogenous interferences (not detected). The method was applied to 13 authentic samples from cannabis-exposed newborns, which meconium samples had tested positive for cannabis. Twelve cord specimens tested positive for THCCOOH-glucuronide (1.6-19.1 ng/g). We developed and validated a specific and sensitive method for the simultaneous determination of THC, its metabolites, including THC and THCCOOH glucuronides, and CBD in umbilical cord samples by LC-MS/MS. The analysis of authentic samples showed the usefulness of umbilical cord to detect cannabis in utero exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.