The synergistic influences of geometrical, mechanical and thermal mismatches between a skin-contacting medical device and the skin may cause tissue stress concentrations and sharp temperature gradients, both of which contribute to the risk for medical device-related pressure ulcers. In this work, we developed an innovative, integrated experimental bioengineering approach encompassing mechanical stiffness, friction and thermal property studies for testing the biomechanical suitability of a hydrogel-based dressing in prophylaxis of injuries caused by devices. We characterised the viscoelastic stress relaxation of the dressing and determined its long-term elastic modulus. We further measured the coefficient of friction of the hydrogel-based dressing at dressing-device and skin-dressing interfaces, using a tilting-table tribometer. Lastly, we measured the thermal conductivity of the dressing, using a heat-flow meter and infrared thermography-based method. All measurements considered dry and moist conditions, the latter simulating skin perspiration effects. Our results revealed that the long-term stiffness and the thermal conductivity of the hydrogel-based dressing matched the corresponding properties of human skin for both dry and moist conditions. The dressing further demonstrated a relatively high coefficient of friction at its skin-facing and device-facing aspects, indicating minimal frictional sliding. All these properties make the above dressing advantageous for prevention of device-related injuries.friction properties, MDRPUs, pressure injury, thermal conductivity, wound care Key Messages• stiffness/thermal property matching is vital to protect skin from injury by devices • prophylactic dressings must stay in place and should not frictionally slide on skin • a hydrogel-based dressing was experimentally evaluated to address these points
OBJECTIVE To develop a robotic phantom system containing multiple simulated wound replicates to determine the synergy in fluid absorbency and retention (sorptivity) performances and the post-simulated-use mechanical durability of silver-containing gelling fiber primary dressings when used with a secondary dressing, as per clinical practice. METHODS Using a robotic system containing six identical wound simulators, the authors tested the sorptivity performances of the Exufiber Ag + (Mölnlycke Health Care, Gothenburg, Sweden) primary dressing (ExAg-polyvinyl alcohol [PVA]) against a market-leading comparator product, when used with a secondary foam dressing. The durability of the primary dressings after simulated use was further investigated through tensile mechanical testing. RESULTS The ExAg-PVA primary dressing delivered greater fluid amounts for absorbency and retention by the secondary foam dressing, approximately 2- and 1.5-fold more than the comparator dressing pair after 10 and 15 hours, respectively. The ExAg-PVA dressing was also substantially less sensitive to the direction of pulling forces and, accordingly, exhibited post-use mechanical strength that was approximately four and six times greater than that of the other primary dressing (when the latter dressing was tested out-of-alignment with its visible seams) after 10 and 15 hours, respectively. CONCLUSIONS The dynamics of the sorptivity and fluid sharing between primary and secondary dressings and the effect of directional preference of strength of the primary dressings for adequate durability, resulting in safe post-use removals, have been described. The comparative quantification of these capabilities should help clinical and nonclinical decision-makers select dressings that best meet their patient needs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.