Process systems are becoming complex due to a higher dependency among operational variables and complex control loops. Principal component analysis (PCA) is widely used to reduce the dimensionality of the complex process systems, while Bayesian networks (BNs) are increasingly employed to model relationships among the operational variables. This article integrates these two methods (BN and PCA) through a logic‐based approach to study the fault conditions of a process system. A distillation pilot plant is used to test the integrated approach. The process monitoring data are analyzed using the PCA to identify the abnormality variables while the BN is developed using data‐driven learning. The variable dependency in the BN nodes is learned through maximum likelihood estimation. The results of the proposed approach are compared against the logic‐based full BN model. The study observes that the logic‐based PCA‐BN approach proposed improves the reliability of fault detection. While the logic‐based full BN provides a better understanding of fault propagation path through the unit, which helps track and troubleshoot the detected faults.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.