In vivo assembly of plasmids has become an increasingly used process, as high throughput studies in molecular biology seek to examine gene function. In this study, we investigated the plasmid construction technique called gap repair cloning (GRC) in two closely related species of yeast – Saccharomyces cerevisiae and Candida glabrata. GRC utilizes homologous recombination (HR) activity to join a linear vector and a linear piece of DNA that contains base pair homology. We demonstrate that a minimum of 20 bp of homology on each side of the linear DNA is required for GRC to occur with at least 10% efficiency. Between the two species, we determine that S. cerevisiae is slightly more efficient at performing GRC. GRC is less efficient in rad52 deletion mutants, which are defective in HR in both species. In dnl4 deletion mutants, which perform less non-homologous end joining (NHEJ), the frequency of GRC increases in C. glabrata, whereas GRC frequency only minimally increases in S. cerevisiae, suggesting that NHEJ is more prevalent in C. glabrata. Our studies allow for a model of the fate of linear DNA when transformed into yeast cells. This model is not the same for both species. Most significantly, during GRC, C. glabrata performs NHEJ activity at a detectable rate (>5%), while S. cerevisiae does not. Our model suggests that S. cerevisiae is more efficient at HR because NHEJ is less prevalent than in C. glabrata. This work demonstrates the determinants for GRC and that while C. glabrata has a lower efficiency of GRC, this species still provides a viable option for GRC.
Background: Transtibial pull-out repair of the medial meniscal posterior root (MMPR) has been largely assessed through biomechanical studies. Biomechanically comparing different suture types would further optimize MMPR fixation and affect clinical care. Purpose/Hypothesis: The purpose of this study was to determine the optimal suture material for MMPR fixation. It was hypothesized that ultra high–molecular weight polyethylene (UHMWPE) suture tape would be biomechanically superior to UHMWPE suture and standard suture. Study Design: Controlled laboratory study. Methods: The MMPR attachment was divided in 24 human cadaveric knees and randomly assigned to 3 repair groups: UHMWPE suture tape, UHMWPE suture, and standard suture. Specimens were dissected down to the medial meniscus, and the posterior root attachments were sectioned off the tibia. Two-tunnel transtibial pull-out repair with 2 sutures, as determined by the testing group, was performed. The repair constructs were cyclically loaded between 10 and 30 N at 0.5 Hz for 1000 cycles to mimic the forces experienced on the medial meniscus during postoperative rehabilitation. Displacement was recorded at 1, 50, 100, 500, and 1000 cycles. Ultimate failure load, displacement at failure, and load at 3 mm of displacement (clinical failure) were also recorded. Results: UHMWPE suture tape had significantly less displacement of the medial meniscus when compared with standard suture at 1 (–0.22 mm [95% CI, –0.41 to –0.02]; P = .025) and 50 (–0.35 mm [95% CI, –0.67 to –0.03]; P = .029) cycles. There were no other significant differences observed in displacement between groups at any number of cycles. UHMWPE suture tape had significantly less displacement at the time of failure than standard suture (–3.71 mm [95% CI, –7.17 to –0.24]; P = .034). UHMWPE suture tape had a significantly higher load to reach the clinical failure displacement of 3 mm than UHMWPE suture (15.64 N [95% CI, 0.02 to 31.26]; P = .05). There were no significant differences in ultimate failure load between groups. Conclusion: The meniscal root repair construct with UHMWPE suture tape may be stronger and less prone to displacement than that with standard suture or UHMWPE suture. Clinical Relevance: UHMWPE suture tape may provide better clinical results compared with UHMWPE suture and standard suture.
Anterior shoulder dislocation is a common problem in athletes and has serious implications due to the rate of injury recurrence and the resulting extended time out of play.» There are a variety of management options that address shoulder instability in an in-season athlete, and the decision-making approach should be individualized to the athlete. » Although nonoperative management and return to play in the same season may be a suitable option for a subset of athletes who wish to return to play as soon as possible (during a recruiting season, for an upcoming Combine, or if they are in the last season of their career), given the high risk of recurrence, we recommend that immediate surgical intervention should be considered to decrease the risk of further damage to the glenohumeral joint.» Arthroscopic stabilization currently is the most commonly performed intervention for athletes with anterior shoulder instability in the United States, but open repair remains an excellent option for high-risk patients.» In collision athletes with subcritical glenoid bone loss between 13.5% and 25%, early open anterior capsulolabral reconstruction or a Latarjet procedure is recommended. If glenoid bone loss exceeds 25%, the Latarjet or another glenoid osseous augmentation procedure should be performed to reduce the risk of recurrent anterior instability.
Diabetics have a much greater prevalence of trigger finger than nondiabetics and are more likely to have severe symptoms. Diabetic trigger finger may be more accurately described on a spectrum of diabetic hand pathology alongside carpal tunnel syndrome and cheiroarthropathy. Recent publications have called into question the current treatment algorithm for diabetic trigger finger. Although some evidence supports the use of corticosteroid injections, a recent cost analysis reported that immediate surgical release of the A1 pulley in the clinic is the most cost-effective management of diabetic trigger finger. In addition to traditional treatment with injection and open release, percutaneous release with or without simultaneous corticosteroid injection has shown promising results and may have a role in patient care. The appropriate treatment algorithm in terms of efficacy, safety, and cost remains controversial.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.