MATERIALS AND METHODS:Forty-four patients with unilateral tibial diaphyseal fractures were treated with intramedullary nails or Ender pins. Twenty patients were treated with an unreamed intramedullary nail with access via the patellar tendon with static locking. Twenty-four patients were treated with Ender pins introduced medially and laterally with respect to the tuberosity of the tibia. The main parameters analyzed were type of reduction, complications, union rate, deformities, joint mobility, pain, gait, effort capacity, presence of neurovascular disorders, and complaints related to the synthesis material. RESULTS: During 1 year of follow-up, the fractures of 90.0% of the patients with intramedullary nails and 95.7% of patients with Ender pins healed within an average of 21.5 weeks and 20.9 weeks, respectively. The significant findings were as follows: patients treated with Ender pins had less mobility of the subtalar joint; patients treated with intramedullary nails were more likely to have pain in the knee; both groups showed shortening of the tibia at the end of 1 year of treatment.
CONCLUSIONS:The two methods are similar in the treatment of type A, B, and C2 tibial diaphyseal fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.