DTI was able to detect that the decrease of the number of the PNFs after RP was statistically related to the post-surgical erectile dysfunction (p < 0.05). Advances in knowledge: This work demonstrates that: (1) 1.5 T MRI DTI is able to detect the decrease of the number and of the FA of PNFs after prostatectomy; (2) the decrease of the number of PNFs after prostatectomy is related with the post-surgical erectile dysfunction; (3) 1.5 T MRI DTI has demonstrated to be a reproducible technique in detecting the changes of the PNFs induced by RP, with high interobserver agreement.
Purpose. Computer-assisted stereolithographically guided surgery allows an ideal implant placement for prosthetic restoration. Two types of stereolithographic templates are currently available: a fully guided template and a pilot-drill guided template. The purpose of this study was (i) to evaluate the accuracy of implant insertion using these types of surgical templates and (ii) to define parameters influencing accuracy. Materials and Methods. 20 patients were enrolled and divided into 2 study groups: in group A, implants were placed using CAD-CAM templates with fully guided sleeves; in group B, implants were placed with a template with only pilot-drill guided sleeves. Pre- and postoperative computed tomographies were used to measure differences between final positions of implants and virtually planned positions. Three linear discrepancies (coronal, apical, and depth) and two angular ones (buccolingual and mesiodistal) were measured. Correlations between accuracy and jaws of interest, implant length and diameters, and type of edentulism were also analysed. Results. A total of 50 implants were inserted in 15 patients using CAD-CAM templates: 23 implants in group A and 27 in group B. The mean coronal deviations were 1.16 and 1.11 mm (P = 0.35), respectively; the mean apical deviations were 1.65 and 1.71 mm (P = 0.22); the mean depth deviations were 0.95 and −0.68 mm (P = 0.032); the mean buccolingual angular deviations were 4.16° and 6.72° (P = 0.042); and the mean mesiodistal ones were 2.81° and 5.61° (P = 0.029). In addition, the accuracy was statistically influenced only by implant diameter for coronal discrepancy (P = 0.035) and by jaw of interest for mesiodistal angulation (P = 0.045). Conclusion. Fully guided implant surgery was more accurate than pilot-drill guided surgery for different parameters. For both types of surgery, a safety margin of at least 2mm should be preserved during implant planning to prevent damage to nearby anatomical structures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.