We describe, for the first time the use of hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) (11.1% w/w) and poly(ethyleneglycol) 10,000 daltons (5.6% w/w) and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min) analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL) and highest (35 μg/mL) Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration extracted from MN was 4.29 nmol/L, detected after 3 hours skin insertion in human volunteers. Whilst not directly correlated, concentrations extracted from MN were clearly indicative of trends in blood in both rats and human volunteers. This work strongly illustrates the potential of hydrogel-forming MN in minimally-invasive patient monitoring and diagnosis. Further studies are now ongoing to reduce clinical insertion times and develop mathematical algorithms enabling determination of blood levels directly from MN measurements.
Since first identified in late 2019, the acute respiratory syndrome coronavirus (SARS-CoV2) and the resulting coronavirus disease (COVID-19) pandemic has overwhelmed healthcare systems worldwide, often diverting key resources in a bid to meet unprecedented challenges. To measure its impact on national antimicrobial stewardship (AMS) activities, a questionnaire was designed and disseminated to antimicrobialstewardship leads in the United Kingdom (UK). Most respondents reported a reduction in AMS activity with 64% (61/95) reporting that COVID-19 had a negative impact on routine AMS activities. Activities reported to have been negatively affected by the pandemic include audit, quality improvement initiatives, education, AMS meetings, and multidisciplinary working including ward rounds. However, positive outcomes were also identified, with technology being increasingly used as a tool to facilitate stewardship, e.g., virtual meetings and ward rounds and increased the acceptance of using procalcitonin tests to distinguish between viral and bacterial infections. The COVID-19 pandemic has had a significant impact on the AMS activities undertaken across the UK. The long-term impact of the reduced AMS activities on incidence of AMR are not yet known. The legacy of innovation, use of technology, and increased collaboration from the pandemic could strengthen AMS in the post-pandemic era and presents opportunities for further development of AMS.
We describe, for the first time, hydrogel-forming microneedle (s) (MN) arrays for minimally-invasive extraction and quantification of lithium in vitro and in vivo. MN arrays, prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) and crosslinked by poly(ethyleneglycol), imbibed interstitial fluid (ISF) upon skin insertion. Such MN were always removed intact. In vitro, mean detected lithium concentrations showed no significant difference following 30min MN application to excised neonatal porcine skin for lithium citrate concentrations of 0.9 and 2mmol/l. However, after 1h application, the mean lithium concentrations extracted were significantly different, being appropriately concentration-dependent. In vivo, rats were orally dosed with lithium citrate equivalent to 15mg/kg and 30mg/kg lithium carbonate, respectively. MN arrays were applied 1h after dosing and removed 1h later. The two groups, having received different doses, showed no significant difference between lithium concentrations in serum or MN. However, the higher dosed rats demonstrated a lithium concentration extracted from MN arrays equivalent to a mean increase of 22.5% compared to rats which received the lower dose. Hydrogel-forming MN clearly have potential as a minimally-invasive tool for lithium monitoring in outpatient settings. We will now focus on correlation between serum and MN lithium concentrations.
The susceptibility of Staphylococcus aureus [meticillin-resistant (MRSA) and meticillin-sensitive (MSSA)] and coagulase-negative staphylococci (CoNS), which respectively form part of the transient and commensal skin flora, to tea-tree oil (TTO) was compared using broth microdilution and quantitative in vitro time-kill test methods. MRSA and MSSA isolates were significantly less susceptible than CoNS isolates, as measured by both MIC and minimum bactericidal concentration. A significant decrease in the mean viable count of all isolates in comparison with the control was seen at each time interval in time-kill assays. However, the only significant difference in the overall mean log 10 reduction in viable count between the groups of isolates was between CoNS and MSSA at 3 h, with CoNS isolates demonstrating a significantly lower mean reduction. To provide a better simulation of in vivo conditions on the skin, where bacteria are reported to grow as microcolonies encased in glycocalyx, the bactericidal activity of TTO against isolates grown as biofilms was also compared. Biofilms formed by MSSA and MRSA isolates were completely eradicated following exposure to 5 % TTO for 1 h. In contrast, of the biofilms formed by the nine CoNS isolates tested, only five were completely killed, although a reduction in viable count was apparent for the other four isolates. These results suggest that TTO exerts a greater bactericidal activity against biofilm-grown MRSA and MSSA isolates than against some biofilm-grown CoNS isolates.
A microwave (MW)‐assisted crosslinking process to prepare hydrogel‐forming microneedle (MN) arrays was evaluated. Conventionally, such MN arrays are prepared using processes that includes a thermal crosslinking step. Polymeric MN arrays were prepared using poly(methyl vinyl ether‐alt‐maleic acid) crosslinked by reaction with poly(ethylene glycol) over 24 h at 80 °C. Polymeric MN arrays were prepared to compare conventional process with the novel MW‐assisted crosslinking method. Infrared spectroscopy was used to evaluate the crosslinking degree, evaluating the area of the carbonyl peaks (2000–1500 cm−1). It was shown that, by using the MW‐assisted process, MN with a similar crosslinking degree to those prepared conventionally can be obtained in only 45 min. The effects of the crosslinking process on the properties of these materials were also evaluated. For this purpose swelling kinetics, mechanical characterisation, and insertion studies were performed. The results suggest that MN arrays prepared using the MW assisted process had equivalent properties to those prepared conventionally but can be produced 30 times faster. Finally, an in vitro caffeine permeation across excised porcine skin was performed using conventional and MW‐prepared MN arrays. The release profiles obtained can be considered equivalent, delivering in both cases 3000–3500 μg of caffeine after 24 h.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.