PurposeRadiotherapy (RT) has played a significant role in treating non melanoma skin cancer (NMSC). High-dose-rate brachytherapy (HDR-BT) approaches have a paramount relevance due to their adaptability, patient protection, and variable dose fractionation schedules. Several innovative applicators have been introduced to the brachytherapy community. The Valencia applicator is a new superficial device that improves the dose distribution compared with the Leipzig applicator. The purpose of this work is to assess the tumor control, cosmesis, and toxicity in patients with NMSC treated with the Valencia applicator and a new regimen of hypofractionation.Material and methodsFrom January 2008 to March 2010, 32 patients with 45 NMSC lesions were treated with the Valencia applicator in the Hospital La Fe. The gross tumor volume was visually assessed, but the tumor depth was evaluated using ultrasound imaging. All lesions for the selected cases were limited to 4 mm depth. The prescription dose was 42 Gy in 6 or 7 fractions (biologically effective dose [BED] ≈ 70 Gy), delivered twice a week.ResultsNinety-eight percent of the lesions were locally controlled at 47 months from treatment. Ninety-three percent of patients were out at least 36 months from treatment. The treatment was well tolerated in all cases. The highest skin toxicity was grade 1 RTOG/EORTC, having resolved with topical treatment at 4 weeks in all but one case which required 2 months. There were no grade 2 or higher late adverse events.ConclusionsIn patients with superficial basal cell carcinoma lesions less than 25 mm in maximum diameter, HDRBT treatment with the Valencia applicator using a hypofractionated regimen provides excellent results, for both cosmetic and local control at a minimum of 3 years follow-up. Moreover, the shorter hypofractionated regimen facilitates compliance, which is very relevant for the elderly patients in our series. Valencia applicators offer a simple, safe, quick, and attractive nonsurgical treatment option.
UFT combined with RT is safe and effective. In resectable rectal cancer, if preoperative treatment is considered, this approach can be an option.
PurposeTo evaluate efficacy and toxicity after salvage brachytherapy (BT) in prostate local recurrence after radiation therapy.Methods and materialsBetween 1993 and 2007, we retrospectively analyzed 56 consecutively patients (pts) undergoing salvage brachytherapy. After local biopsy-proven recurrence, pts received 145 Gy LDR-BT (37 pts, 66%) or HDR-BT (19 pts, 34%) in different dose levels according to biological equivalent doses (BED2 Gy). By the time of salvage BT, only 15 pts (27%) received ADT. Univariate and multivariate analyses were performed to identify predictors of biochemical control and toxicities. Acute and late genitourinary (GU) and gastrointestinal (GI) toxicities were graded using Common Terminology Criteria for Adverse Events (CTCv3.0).ResultsMedian follow-up after salvage BT was 48 months. The 5-year FFbF was 77%. HDR and LDR late grade 3 GU toxicities were observed in 21% and 24%. Late grade 3 GI toxicities were observed in 2% (HDR) and 2.7% (LDR). On univariate analysis, pre-salvage prostate-specific antigen (PSA) > 10 ng/ml (p = 0.004), interval to relapse after initial treatment < 24 months (p = 0.004) and salvage HDR-BT doses BED2 Gy level < 227 Gy (p = 0.012) were significant in predicting biochemical failure. On Cox multivariate analysis, pre-salvage PSA, and time to relapse were significant in predicting biochemical failure.HDR-BT BED2 Gy (α/β 1.5 Gy) levels ≥ 227 (p = 0.013), and ADT (p = 0.049) were significant in predicting grade ≥ 2 urinary toxicity.ConclusionsProstate BT is an effective salvage modality in some selected prostate local recurrence patients after radiation therapy. Even, we provide some potential predictors of biochemical control and toxicity for prostate salvage BT, further investigation is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.