In previous studies, mechanical dispersion (MD) predicted ventricular arrhythmias independently of left ventricular ejection fraction (LVEF). Moreover, the combination of MD and global longitudinal strain (GLS) increased the prediction of arrhythmic events. We investigated the prognostic value of a new 2-dimensional strain index, GLS/MD, in patients with heart failure (HF). We analyzed 340 consecutive HF outpatients in sinus rhythm. Echocardiography was performed at 1.6 ± 0.4 months after hospital discharge. The end point included sudden cardiac death, ventricular fibrillation, and sustained ventricular tachycardia (SCD/VA). During the follow-up period (36 ± 9 months), SCD/VA occurred in 48 patients (14.1%). A multivariate Cox regression analysis, which included LVEF, early diastolic transmitral / mitral annular velocity ratio (E/E'), GLS, MD, and GLS/MD in the model, revealed that GLS/MD was the best independent predictor of SCD/VA (HR = 3.22, 95% confidence interval = 1.72-6.15, p = 0.03). Separate inclusion of LVEF, systolic mitral annular velocity, E/E', GLS, and MD together with GLS/MD showed that GLS/MD remained the best predictor of SCD/VA (each p < 0.05). The optimal GLS/MD cutoff value to predict SCA/VA was -0.20%/ms (80% sensitivity, 76% specificity). Irrespective of LVEF, free survival was significantly better in patients with GLS/MD ≤ -0.2%/ms (log-rank test, p < 0.001). In conclusion, GLS/MD may improve cardiovascular risk stratification in subjects with HF.
We report the case of a 48-year-old man, admitted for atrial fibrillation with rapid heart rate and intense chest pain. A quick evaluation revealed a giant aortic aneurysm with severe aortic regurgitation and pericardial fluid without a trace of aortic dissection. Because of high suspicion of aortic rupture, an emergency surgery was planned, and a Bentall procedure was performed. On examination of the aortic wall revealing vertical wrinkling with a tree bark aspect, suspicion of syphilitic aortitis arose. The diagnosis was confirmed through postoperative serologic testing and histological examination. Histopathologic differential diagnosis, special treatment and follow-up are presented.
Background and objectives: Transcatheter aortic valve implantation (TAVI) is a therapeutic choice for high surgical risk patients, serving as an alternative to open-heart surgery. Correct measurement of the aortic annulus, which leads to the selection of a suitable prosthesis and accurate outcome prediction, is essential for the success of TAVI. The objective of this study is to evaluate the accuracy of novel imaging te chniques in measuring the aortic annulus by comparing multi-detector computer tomography (MDCT) and three-dimensional transesophageal echocardiography (3D TEE) for the selection of the optimal prosthesis. Materials and Methods: Measurements of the aortic annulus have been performed on 25 patients using MDCT and TEE, and the correlation and agreement levels between the two measuring techniques were analyzed. MDCT measurements were used for the sizing of the prostheses. Results: MDCT and TEE measurements of aortic annular diameters were significantly correlated, with a mean difference of 0.001 cm. Conclusions: 3D TEE measurements have been in good agreement with MDCT and, therefore, 3D TEE can be used as an alternative in cases where MDCT is contraindicated or not available.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.